MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10877-025-01284-0

Медицинская библиотека · Journal of clinical monitoring and computing · 2025

Haemodynamic monitoring and management during non-cardiac surgery: a survey among German anaesthesiologists.

Vojnar Benjamin, Achenbach Patrick, Flick Moritz, Reuter Daniel, Sander Michael, Saugel Bernd, Schubert Ann-Kristin, Gaik Christine

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

In 2023, the first German guideline on intraoperative haemodynamic monitoring and management for adults having non-cardiac surgery was published. The aim of this survey was to identify how anaesthetists in Germany managed intraoperative haemodynamics and blood pressure before its publication. In September to October 2023, members of the German Society of Anaesthesiology and Intensive Care Medicine (DGAI) were invited via email to participate in this anonymous online survey. Thirty-one questions covered demographics, clinical experience, approaches to perioperative blood pressure measurement and common thresholds, as well as the use of advanced haemodynamic monitoring and its potential therapeutic implications. 1,079 fully completed questionnaires were included in the analysis. When intermittent oscillometry was used to measure blood pressure, a 3-minute interval was usually applied during induction of anaesthesia (42%; 451/1,079). For invasive blood pressure monitoring, more than half (53%; 574/1,079) inserted an arterial line after induction of anaesthesia. Nearly all (94%; 1,012/1,079) focused on the mean arterial pressure for blood pressure monitoring, with a large majority (77%; 779/1012) considering values below 60-65 mmHg to be critically low. Intraoperative hypotension was managed based on an internal protocol by only 21% (223/1,079). Regarding advanced haemodynamic monitoring, 43% (459/1,079) frequently used pulse contour analysis, while 67% (721/1,079) reported that monitors with finger-cuff technology were not available in their department. 47% (504/1,079) cited a lack of experience as one of the main reasons for the infrequent use of cardiac output monitoring. This survey among DGAI members provides important insights into current practices of haemodynamic monitoring and management prior to the publication of the recent German guideline on 'Intraoperative haemodynamic monitoring and management of adults having non-cardiac surgery'.

Для цитирования: Vojnar Benjamin, Achenbach Patrick, Flick Moritz, Reuter Daniel, Sander Michael, Saugel Bernd, Schubert Ann-Kristin, Gaik Christine. Haemodynamic monitoring and management during non-cardiac surgery: a survey among German anaesthesiologists.. Journal of clinical monitoring and computing. 2025. DOI: 10.1007/s10877-025-01284-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.