Use of MALDI Biotyper plus ClinProTools mass spectra analysis for correct identification of Streptococcus pneumoniae and Streptococcus mitis/oralis.

Chen Jonathan H K, She Kevin K K, Wong Oi-Ying, Teng Jade L L, Yam Wing-Cheong, Lau Susanna K P, Woo Patrick C Y, Cheng Vincent C C, Yuen Kwok-Yung

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Differentiation of Streptococcus pneumoniae from other viridans group streptococci is well known to be challenging in clinical laboratories. Matrix assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) had been reported to be a good alternative for Streptococcus species level identification. However, differentiation of S. pneumoniae from other Streptococcus mitis group organisms was found to be problematic using the Bruker MALDI Biotyper system.

METHODS

This study used the Bruker MALDI Biotyper system in addition to a mass spectra model analysis generated by 10 reference strains of S. pneumoniae, 8 strains of S. mitis and 2 strains of S. oralis in the ClinProTools to identify 28 clinical isolates of S. pneumoniae and 47 isolates of S. mitis/oralis. The results were compared with those generated by the MALDI Biotyper system alone.

RESULTS

The percentages of correct species level identification using the MALDI Biotyper system alone and the direct transfer and extraction method were 66.7% (50/75) and 70.7% (53/75), respectively. With the additional ClinProTools mass spectra analysis, the percentages of correct identification by the direct transfer and extraction method increased to 85.3% (64/75) and 100% (75/75), respectively. This new workflow significantly improved the accuracy of S. pneumoniae and S. mitis/oralis identification.

CONCLUSIONS

The additional ClinProTools mass spectra analysis with extraction method after MALDI Biotyper identification significantly improved the accuracy of identification among S. pneumoniae, S. oralis and S. mitis. The extra 15 min processing time of spectra analysis should be affordable in most clinical laboratories. We suggest that the same approach could be further explored in handling other bacterial species with high similarities.

Для цитирования: Chen Jonathan H K, She Kevin K K, Wong Oi-Ying, Teng Jade L L, Yam Wing-Cheong, Lau Susanna K P, Woo Patrick C Y, Cheng Vincent C C, Yuen Kwok-Yung. Use of MALDI Biotyper plus ClinProTools mass spectra analysis for correct identification of Streptococcus pneumoniae and Streptococcus mitis/oralis.. Journal of clinical pathology. 2015. DOI: 10.1136/jclinpath-2014-202818.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.