MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15563316221114135

Медицинская библиотека · HSS journal : the musculoskeletal journal of Hospital for Special Surgery · 2022

Biomechanical Comparison of Synthetic Polytetrafluoroethylene (PTFE) vs Human Dermal Allograft (HDA), 2 vs 3 Glenoid Anchors, and Suture vs Minitape in Superior Capsule Reconstruction.

Ting Ryan S, Guo Allen A, Rosenthal Ron, Al-Housni Hilal S A, Lam Patrick H, Murrell George A C

СтатьяПеревод пока не подготовлен

Аннотация

Background

Superior capsule reconstruction (SCR) is an option for the treatment of massive, irreparable rotator cuff tears. However, which materials yield the strongest constructs remains undetermined. Purposes: We sought to investigate whether SCR with polytetrafluoroethylene (PTFE) or human dermal allograft (HDA), 2 or 3 glenoid anchors, and suture or minitape resulted in better failure load properties at the patch-glenoid interface.

Methods

We conducted a biomechanical study in 30 glenoid-sided SCR repairs in Sawbones models divided into 5 groups. Each was pulled to failure to assess mode of failure, peak load (N), stiffness (N/mm), yield load (N), peak energy (N m), and ultimate energy (N m). The 5 groups were as follows: group 1-PTFE, 2 anchors, and suture; group 2-PTFE, 2 anchors, and minitape; group 3-HDA, 2 anchors, and suture; group 4-HDA, 2 anchors, and minitape; group 5-PTFE, 3 anchors, and minitape.

Results

Repairs failed by button-holing of suture/minitape. Group 5 had greater peak load, stiffness, yield load, and peak energy (384 ± 62 N; 24 ± 3 N/mm; 343 ± 42 N; 4 ± 2 N m) than group 3 (226 ± 67 N; 16 ± 4 N/mm; 194 ± 74 N; 2 ± 1 N m) or group 4 (274 ± 62 N; 17 ± 4 N/mm; 244 ± 50 N; 2 ± 1 N m) and greater ultimate energy (8 ± 3 N m) than all other groups.

Conclusions

This biomechanical study of SCR repairs in Sawbones models found that yield load was greater in PTFE than HDA, 3 anchors were better than 2, and minitape was no better than suture.

Для цитирования: Ting Ryan S, Guo Allen A, Rosenthal Ron, Al-Housni Hilal S A, Lam Patrick H, Murrell George A C. Biomechanical Comparison of Synthetic Polytetrafluoroethylene (PTFE) vs Human Dermal Allograft (HDA), 2 vs 3 Glenoid Anchors, and Suture vs Minitape in Superior Capsule Reconstruction.. HSS journal : the musculoskeletal journal of Hospital for Special Surgery. 2022. DOI: 10.1177/15563316221114135.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.