DOI 10.1177/000348941312200605
Preoperative computed tomography scan may fail to predict perilymphatic gusher.
Аннотация
OBJECTIVES
A stapes gusher is a very rare event in ear surgery, but the consequences for hearing can be dramatic. It can usually be predicted by characteristic radiologic abnormalities. We report 2 cases of gusher without any abnormalities seen on the preoperative computed tomography scans.
METHODS
The first case was in a 30-year-old man with a bilateral mixed hearing loss. The gusher occurred after a stapedotomy performed with a microdrill. The oval window was plugged with a vein graft, and a fluoroplastic piston was inserted. The second case was in a 39-year-old woman with a family history of hearing loss who presented with a bilateral mixed hearing loss. The footplate was fractured during the stapedotomy drilling and was covered with a temporalis fascia graft that was fixed with a fluoroplastic piston.
RESULTS
The first patient had no cerebrospinal fluid leakage and no vertigo or tinnitus. He did have a sensorineural hearing loss. The second patient had dizziness and tinnitus. Postoperative magnetic resonance imaging scans were performed, but again no features were identified that might have predicted these cases.
CONCLUSIONS
Surgeons should be reminded that a preoperative computed tomography scan may fail to detect the risk of a perilymphatic gusher.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.