MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0886-3350(02)01637-1

Медицинская библиотека · Journal of cataract and refractive surgery · 2003

Reasons for secondary surgical intervention after phacoemulsification with posterior chamber lens implantation.

Raman Soman, Redmond Richard

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To determine the indications for secondary surgical intervention in patients who had primary phacoemulsification with posterior chamber intraocular lens (IOL) implantation and to assess the final visual outcomes.

SETTING

Department of Ophthalmology, Scarborough Hospital, Scarborough, United Kingdom.

METHODS

The case notes of 17 patients (18 eyes) were reviewed to determine the reasons for secondary surgical intervention. From September 1997 to December 2000 (40 months), 4388 primary phacoemulsification procedures with posterior chamber IOL implantation were performed.

RESULTS

Fifteen eyes required secondary surgical interventions for lens-related factors and 3, for surgeon-related factors. All patients had satisfactory visual outcomes after the secondary intervention.

CONCLUSIONS

The indications for secondary intervention included unsatisfactory refractive outcome, posterior settlement of the IOL, unwanted imagery, inappropriate IOL power, and IOL dislocation. Secondary intervention can be performed safely and provides satisfactory final visual outcomes.

Для цитирования: Raman Soman, Redmond Richard. Reasons for secondary surgical intervention after phacoemulsification with posterior chamber lens implantation.. Journal of cataract and refractive surgery. 2003. DOI: 10.1016/s0886-3350(02)01637-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.