DOI 10.1186/s12880-024-01373-7

Медицинская библиотека · BMC medical imaging · 2024

Contrast enhancement boost improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data.

Yang Lin, Zhang Haiwei, Sheng Jiexin, Wang Meng, Liu Yaliang, Xu Min, Yang Xiao, Wang Bo, He Xiaolong, Gao Lei, Zheng Chao

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVE

To investigate the impact of the contrast enhancement boost (CE-boost) technique on the image quality of CT angiography (CTA) derived from 80-kVp cerebral CT perfusion (CTP) data, and to compare it with conventional CTApeak as well as other currently employed methods for enhancing CTA images, such as CTAtMIP and CTAtAve extracted from CTP.

MATERIALS AND

METHODS

The data of forty-seven patients who underwent CTP at 80 kVp were retrospectively collected. Four sets of images: CTApeak, CTAtMIP, CTAtAve, and CE-boost images. The CTApeak image represents the arterial phase at its peak value, captured as a single time point. CTAtMIP and CTAtAve are 4D CTA images that provide maximum density projection and average images from the three most prominent time points. CE-boost is a postprocessing technique used to enhance contrast in the arterial phase at its peak value. We compared the average CT value, standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the internal carotid artery (ICA) and basilar artery (BA) among the four groups. Image quality was evaluated using a 5-point scale.

RESULTS

The CE-boost demonstrated and CNR in the ICA and BA (all p < 0.001). Compared with the other three CTA reconstructed images, the CE-boost images had the best subjective image quality, with the highest scores of 4.77 ± 0.43 and 4.87 ± 0.34 for each reader (all p < 0.001).

CONCLUSION

Compared with other currently used techniques,CE-boost enhances the image quality of CTA derived from 80-kVp CTP data, leading to improved visualization of intracranial arteries.

Для цитирования: Yang Lin, Zhang Haiwei, Sheng Jiexin, Wang Meng, Liu Yaliang, Xu Min, Yang Xiao, Wang Bo, He Xiaolong, Gao Lei, Zheng Chao. Contrast enhancement boost improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data.. BMC medical imaging. 2024. DOI: 10.1186/s12880-024-01373-7.