MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00062-024-01435-x

Медицинская библиотека · Clinical neuroradiology · 2024

Comparative Efficacy of Flow Diverter Devices in the Treatment of Carotid Sidewall Intracranial Aneurysms: a Retrospective, Multicenter Study.

Dmytriw Adam A, Salim Hamza Adel, Musmar Basel, Cancelliere Nicole M, Griessenauer Christoph J, Regenhardt Robert W, Jones Jesse, Tutino Vincent, Hasan Zuha, Limbucci Nicola, Lay Sovann V, Spears Julian, Rabinov James D, Harrigan Mark R, Siddiqui Adnan H, Levy Elad I, Stapleton Christopher J, Renieri Leonardo, Cognard Christophe, Shaikh Hamza, Kühn Anna Luisa, Möhlenbruch Markus A, Tjoumakaris Stavropoula I, Jabbour Pascal, Taussky Philipp, Settecase Fabio, Heran Manraj K S, Nguyen Anh, Volders David, Harker Pablo, Devia Diego A, Puri Ajit S, Psychogios Marios, Puentes Juan C, Leone Giuseppe, Buono Giuseppe, Tarantino Margherita, Muto Mario, Briganti Francesco, Dalal Shamsher, Gontu Vamsi, Alcedo Guardia Rodolfo E, Vicenty-Padilla Juan C, Brouwer Patrick, Schmidt Matthias H, Schirmer Clemens, Pickett Gwynedd E, Andersson Tommy, Söderman Michael, Marotta Thomas R, Cuellar-Saenz Hugo, Thomas Ajith J, Patel Aman B, Mendes Pereira Vitor, Adeeb Nimer, Flow diversion Multinational Observational cohort Device comparsion (FlowMOD) Investigators

СтатьяМногоцентровое исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

The comparative efficacy and safety of first-generation flow diverters (FDs), Pipeline Embolization Device (PED) (Medtronic, Irvine, California), Silk (Balt Extrusion, Montmorency, France), Flow Re-direction Endoluminal Device (FRED) (Microvention, Tustin, California), and Surpass Streamline (Stryker Neurovascular, Fremont, California), is not directly established and largely inferred.

PURPOSE: This study aimed to compare the efficacy of different FDs in treating sidewall ICA intracranial aneurysms.

METHODS

We conducted a retrospective review of prospectively maintained databases from eighteen academic institutions from 2009-2016, comprising 444 patients treated with one of four devices for sidewall ICA aneurysms. Data on demographics, aneurysm characteristics, treatment outcomes, and complications were analyzed. Angiographic and clinical outcomes were assessed using various imaging modalities and modified Rankin Scale (mRS). Propensity score weighting was employed to balance confounding variables. The data analysis used Kaplan-Meier curves, logistic regression, and Cox proportional-hazards regression.

RESULTS

While there were no significant differences in retreatment rates, functional outcomes (mRS 0-1), and thromboembolic complications between the four devices, the probability of achieving adequate occlusion at the last follow-up was highest in Surpass device (HR: 4.59; CI: 2.75-7.66, p < 0.001), followed by FRED (HR: 2.23; CI: 1.44-3.46, p < 0.001), PED (HR: 1.72; CI: 1.10-2.70, p = 0.018), and Silk (HR: 1.0 ref. standard). The only hemorrhagic complications were with Surpass (1%).

CONCLUSION

All the first-generation devices achieved good clinical outcomes and retreatment rates in treating ICA sidewall aneurysms. Prospective studies are needed to explore the nuanced differences between these devices in the long term.

Для цитирования: Dmytriw Adam A, Salim Hamza Adel, Musmar Basel, Cancelliere Nicole M, Griessenauer Christoph J, Regenhardt Robert W, Jones Jesse, Tutino Vincent, Hasan Zuha, Limbucci Nicola, Lay Sovann V, Spears Julian, Rabinov James D, Harrigan Mark R, Siddiqui Adnan H, Levy Elad I, Stapleton Christopher J, Renieri Leonardo, Cognard Christophe, Shaikh Hamza, Kühn Anna Luisa, Möhlenbruch Markus A, Tjoumakaris Stavropoula I, Jabbour Pascal, Taussky Philipp, Settecase Fabio, Heran Manraj K S, Nguyen Anh, Volders David, Harker Pablo, Devia Diego A, Puri Ajit S, Psychogios Marios, Puentes Juan C, Leone Giuseppe, Buono Giuseppe, Tarantino Margherita, Muto Mario, Briganti Francesco, Dalal Shamsher, Gontu Vamsi, Alcedo Guardia Rodolfo E, Vicenty-Padilla Juan C, Brouwer Patrick, Schmidt Matthias H, Schirmer Clemens, Pickett Gwynedd E, Andersson Tommy, Söderman Michael, Marotta Thomas R, Cuellar-Saenz Hugo, Thomas Ajith J, Patel Aman B, Mendes Pereira Vitor, Adeeb Nimer, Flow diversion Multinational Observational cohort Device comparsion (FlowMOD) Investigators. Comparative Efficacy of Flow Diverter Devices in the Treatment of Carotid Sidewall Intracranial Aneurysms: a Retrospective, Multicenter Study.. Clinical neuroradiology. 2024. DOI: 10.1007/s00062-024-01435-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.