MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23736/s0021-9509.24.13121-7

Медицинская библиотека · The Journal of cardiovascular surgery · 2024

Next-generation transcarotid artery revascularization: TransCarotid flOw Reversal Cerebral Protection And CGUARD MicroNET-Covered Embolic Prevention Stent System To Reduce Strokes - TOPGUARD Study.

Trystula Mariusz, VAN Herzeele Isabelle, Kolvenbach Ralf, Tekieli Lukasz, Fonteyne Charlotte, Mazurek Adam, Dzierwa Karolina, Chmiel Jakub, Lindsay Julie, Kwiatkowski Tomasz, Hydzik Adam, Oplawski Maksymilian, Bederski Krzysztof, Musialek Piotr

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Stent-assisted carotid artery revascularization employing surgical cutdown for transcervical access and dynamic flow reversal (TCAR) is gaining popularity. TCAR, despite maximized intra-procedural cerebral protection, shows a marked excess of 30-day neurologic complications in symptomatic vs. asymptomatic stenoses. The TCAR conventional single-layer stent (free-cell area 5.89mm2) inability to seal embologenic lesions may be particularly relevant after the flow reversal neuroprotection is terminated.

METHODS

We evaluated peri-procedural and 30-day major adverse cerebral and cardiac events (MACCE) of TCAR (ENROUTE, SilkRoad Medical) paired with MicroNET-covered neuroprotective stent (CGuard, InspireMD) in consecutive patients at elevated risk of complications with transfemoral/transradial filter-protected stenting (increased lesion-related and/or access-related risk). CGuard (MicroNET free cell area ≈0.02-0.03 mm2) has level-1 evidence for reducing intra- and abolishing post-procedural lesion-related cerebral embolism.

RESULTS

One hundred and six increased-risk patients (age 72 [61-76] years, median [Q1-Q3]; 60.4% symptomatic, 49.1% diabetic, 36.8% women, 61.3% left-sided index lesion) were enrolled in three vascular surgery centers. Angiographic stenosis severity was 81 (75-91)%, lesion length 21 (15-26)mm, increased-risk lesional characteristics 87.7%. Study stent use was 100% (no other stent types). 74.5% lesions were predilated; post-dilatation rate was 90.6%. Flow reversal duration was 8 (5-11)min. One stroke (0.9%) occurred in an asymptomatic patient prior to establishing neuroprotection (index lesion disruption with the sheath insertion wire); there were no other peri-procedural MACCE. No further adverse events occurred by 30-days. 30-day stent patency was 100% with normal velocities and absence of any in-stent material by Duplex Doppler.

CONCLUSIONS

Despite a high proportion of increased-risk lesions and clinically symptomatic patients in this study, TCAR employing the MicroNET-covered anti-embolic stent showed 30-day MACCE rate <1%. This suggests a clinical role for combining maximized intra-procedural prevention of cerebral embolism by dynamic flow reversal with anti-embolic stent prevention of peri- and post-procedural cerebral embolism (TOPGUARD NCT04547387).

Для цитирования: Trystula Mariusz, VAN Herzeele Isabelle, Kolvenbach Ralf, Tekieli Lukasz, Fonteyne Charlotte, Mazurek Adam, Dzierwa Karolina, Chmiel Jakub, Lindsay Julie, Kwiatkowski Tomasz, Hydzik Adam, Oplawski Maksymilian, Bederski Krzysztof, Musialek Piotr. Next-generation transcarotid artery revascularization: TransCarotid flOw Reversal Cerebral Protection And CGUARD MicroNET-Covered Embolic Prevention Stent System To Reduce Strokes - TOPGUARD Study.. The Journal of cardiovascular surgery. 2024. DOI: 10.23736/s0021-9509.24.13121-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.