Accurate pre-operative localization of pathological parathyroid glands using 11C-methionine PET/CT.

Tang Bich-Ngoc-Thanh, Moreno-Reyes Rodrigo, Blocklet Didier, Corvilain Bernard, Cappello Matteo, Delpierre Isabelle, Devuyst France, Van Simaeys Gaetan, Goldman Serge

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

The pre-operative technique most routinely used to localize pathological parathyroid glands (PPG), prior to minimal access surgery (MAS), relies on 99mTc-sestamibi (MIBI) scintigraphy. Positron emission tomography (PET) using the radiolabelled amino acid 11C-methionine as the tracer agent offers a technological alternative to localize PPG. In this study we evaluated the sensitivity of 11C-methionine PET/CT (MET-PET/CT) for PPG detection and the extent to which MET-PET/CT images may contribute to the planning of surgical procedures.

DESIGN

Thirty patients were included, 22 with primary hyperparathyroidism and eight with secondary hyperparathyroidism. Patients suspected of suffering from parathyroid hyperplasia underwent a complete surgical exploration of the neck region. In those suspected of parathyroid adenoma, surgery was limited to the presumed localization described by MET-PET/CT. To specifically address the additional benefit of the MET-PET/CT in terms of surgical planning and procedure, the surgeon classified the patients into two categories depending on the type of benefit, or the reason for the absence of benefit, occurring in each case. We also compared the sensitivity of MET-PET/CT and MIBI scintigraphy.

RESULTS

The total number of lesions removed was 46 (24 adenomatous and 22 hyperplastic). Globally, MET-PET/CT provided additional benefit to surgery in 15 out of 30 cases (50%). The sensitivity of 11C-methionine PET/CT and MIBI scintigraphy was respectively 92% and 95% for adenoma, and 68% and 59% for hyperplasia, on the basis of available resected lesions.

CONCLUSION

MET-PET/CT appears a reliable technique to guide MAS of parathyroid glands.

Для цитирования: Tang Bich-Ngoc-Thanh, Moreno-Reyes Rodrigo, Blocklet Didier, Corvilain Bernard, Cappello Matteo, Delpierre Isabelle, Devuyst France, Van Simaeys Gaetan, Goldman Serge. Accurate pre-operative localization of pathological parathyroid glands using 11C-methionine PET/CT.. Contrast media & molecular imaging. 2008. DOI: 10.1002/cmmi.243.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.