m+Medelevator.RU
← Поиск публикаций
Heart rhythm · 2018

Outcomes following implantable cardioverter-defibrillator generator replacement in patients with recovered left ventricular systolic function: The National Cardiovascular Data Registry.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Thomas Isac C, Wang Yongfei, See Vincent Y, Minges Karl E, Curtis Jeptha P, Hsu Jonathan C

Аннотация

BACKGROUND: Some patients with heart failure (HF) experience recovery of left ventricular (LV) systolic function by the end of their implantable cardioverter-defibrillator (ICD) generator battery life. Outcomes following generator replacement in this setting are poorly understood.

OBJECTIVE: We sought to describe outcomes following ICD generator replacement associated with recovery of LV systolic function.

METHODS: We evaluated 26,197 Medicare beneficiaries enrolled in the American College of Cardiology's National Cardiovascular Data Registry ICD Registry who underwent primary prevention ICD generator replacement between 2006 and 2009, stratified by LV ejection fraction (LVEF): reduced (LVEF ≤35%), partially recovered (LVEF >35% and ≤50%), and recovered (LVEF >50%).

RESULTS: At the time of generator replacement, 1915 (7.3%) patients had recovered LVEF and 4576 (17.5%) had partially recovered LVEF. Periprocedural events were rare (<1%) in all patients. In patients with reduced LVEF, the incidence of HF readmission and mortality at 3 years was 27.5% and 32.7%, respectively. In comparison, the rates of HF readmission and mortality were lower for patients with partially recovered LVEF (readmission: 15.9%; hazard ratio [HR] 0.66; 95% confidence interval [CI] 0.61-0.72; mortality: 23.0%; HR 0.82; 95% CI 0.76-0.87) and those with recovered LVEF (readmission: 12.2%; HR 0.55; 95% CI 0.48-0.63; mortality: 18.2%; HR 0.72; 95% CI 0.64-0.80).

CONCLUSION: Patients with partially recovered and recovered LVEF have lower risks of mid-term adverse outcomes than do those with reduced LVEF following ICD generator replacement. Approximately 3 in 4 patients continue to have reduced LVEF at the time of generator replacement and are at high risk of HF readmission and mortality. These data highlight the prognostic associations of LVEF in patients undergoing generator replacement as well as the clinical encounter for generator replacement as an opportunity to identify those at increased risk of adverse outcomes.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты