Медицинская библиотека · Journal of perinatology : official journal of the California Perinatal Association · 2018

Does ultrasound guidance for peripherally inserted central catheter (PICC) insertion reduce the incidence of tip malposition? - a randomized trial.

Oleti Tejopratap, Jeeva Sankar M, Thukral Anu, Sreenivas V, Gupta Arun Kumar, Agarwal Ramesh, Deorari Ashok K, Paul Vinod K

СтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aim of the study was to evaluate the incidence of peripheral inserted central catheter (PICC) tip malposition when the catheter is inserted under real-time ultrasound (RTUS) guidance when compared with conventional landmark (CL) technique in neonates. Additional objectives were to evaluate the PICC longevity and central line associated blood stream infections (CLABSI).

STUDY

DESIGN

In this randomised controlled trial, neonates were randomised to 'RTUS' (n = 40) or 'CL' (n = 40) groups. PICC tip was placed under ultrasound guidance in lower third of superior vena cava in the RTUS group. In 'CL' group, PICC was inserted as calculated by anatomical landmarks.

RESULTS

The birth weight (1286 (926, 1662) vs. 1061 (889, 1636) g) and gestation (31.12 (3.1) vs. 31.4 (3.6) wks) were comparable among the groups. RTUS guidance during PICC insertion reduced incidence of tip malposition by 52% (67.5 vs. 32.5%; RR: 0.48; 95% CI: 0.29-0.79). The longevity of PICC and episodes of CLABSI were however similar in the two groups.

CONCLUSIONS

Real-time ultrasound guidance during PICC placement reduces the incidence of tip malposition.

Для цитирования: Oleti Tejopratap, Jeeva Sankar M, Thukral Anu, Sreenivas V, Gupta Arun Kumar, Agarwal Ramesh, Deorari Ashok K, Paul Vinod K. Does ultrasound guidance for peripherally inserted central catheter (PICC) insertion reduce the incidence of tip malposition? - a randomized trial.. Journal of perinatology : official journal of the California Perinatal Association. 2018. DOI: 10.1038/s41372-018-0249-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.