MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.27891

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2018

Impact of diabetes on clinical outcomes after revascularization with sirolimus-eluting and biolimus-eluting stents with biodegradable polymer from the SORT OUT VII trial.

Ellert Julia, Christiansen Evald Høj, Maeng Michael, Raungaard Bent, Jensen Svend Eggert, Kristensen Steen Dalby, Veien Karsten Tange, Junker Anders Bo, Jakobsen Lars, Aarøe Jens, Terkelsen Christian Juhl, Kahlert Johnny, Villadsen Anton Boel, Bøtker Hans Erik, Jensen Lisette Okkels

Сравнительное исследованиеEquivalence TrialСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

In this substudy of the SORT OUT VII trial, the clinical outcomes among patient with diabetes mellitus treated with Orsiro sirolimus-eluting stent (O-SES; Biotronik, Bülach, Switzerland) or Nobori biolimus-eluting stent (N-BES; Terumo, Tokyo, Japan) were compared.

BACKGROUND

Diabetes is associated with increased risk of target lesion failure (TLF) after percutaneous coronary intervention.

METHODS

In total, 2525 patients were randomized to stent implantation with O-SES (n = 1261, diabetes: n = 236) or N-BES (n = 1264, diabetes: n = 235). The primary endpoint, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 2 years.

RESULTS

At 2 year, TLF did not differ between O-SES vs N-BES in diabetic (9.3% vs 9.4%; RR 0.98, 95% CI 0.54-1.78) patients. The individual components of the primary endpoint did not differ among stent type. In diabetics, cardiac death occurred in 3% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.77, 95% CI 0.29-2.08), MI occurred in 3.0% of O-SES-treated and in 3.8% of N-BES-treated patients (RR 0.76, 95% CI 0.28-2.06) and TLR occurred in 5,5% of O-SES-treated and in 6.0% of N-BES-treated patients (RR 0.91, 95% CI 0.43-1.95).

CONCLUSION

TLF did not differ between O-SES- and N-BES-treated diabetic patients.

Для цитирования: Ellert Julia, Christiansen Evald Høj, Maeng Michael, Raungaard Bent, Jensen Svend Eggert, Kristensen Steen Dalby, Veien Karsten Tange, Junker Anders Bo, Jakobsen Lars, Aarøe Jens, Terkelsen Christian Juhl, Kahlert Johnny, Villadsen Anton Boel, Bøtker Hans Erik, Jensen Lisette Okkels. Impact of diabetes on clinical outcomes after revascularization with sirolimus-eluting and biolimus-eluting stents with biodegradable polymer from the SORT OUT VII trial.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2018. DOI: 10.1002/ccd.27891.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.