Prolonged antimicrobial prophylaxis following cardiac device procedures increases preventable harm: insights from the VA CART program.
Аннотация
BACKGROUND
The rate of cardiovascular implantable electronic device (CIED) infection is increasing coincident with an increase in the number of device procedures. Preprocedural antimicrobial prophylaxis reduces CIED infections; however, there is no evidence that prolonged postprocedural antimicrobials additionally reduce risk. Thus, we sought to quantify the harms associated with this approach.
OBJECTIVE
To measure the association between Clostridium difficile infection (CDI), acute kidney injury (AKI) and receipt of prolonged postprocedural antimicrobials.
METHODS
CIED procedures entered into the VA Clinical Assessment Reporting and Tracking Electrophysiology (CART-EP) database during fiscal years 2008-2016 were included. The primary outcome was 90-day incidence of CDI and the secondary outcome was the 7-day incidence of AKI. The primary exposure measure was duration of postprocedural antimicrobial therapy. Associations were measured using Cox-proportional hazards and binomial regression.
RESULTS
Prolonged postprocedural antimicrobial therapy was identified following 3,331 of 6,497 CIED procedures (51.3%), and the median duration of prophylaxis was 5 days. Prolonged postprocedural antimicrobial use was associated with increased risk of CDI (hazard ratio [HR], 2.90; 95% confidence interval [CI], 1.54-5.46). Of the 27 patients who developed CDI, 11 subsequently died. Postprocedural antimicrobial use with ≥2 antimicrobials was associated with an increased risk of AKI (OR, 4.16; 95% CI, 2.50-6.90). The impact was particularly significant when one of the dual agents prescribed was vancomycin (adjusted OR, 8.41; 95% CI, 5.53-12.79).
CONCLUSIONS
Prolonged antimicrobial prophylaxis following CIED procedures increases preventable harm; this practice should be discouraged in procedural settings such as the cardiac electrophysiology laboratory.