BACKGROUND

There are few data of clinical outcomes after drug-coated balloon (DCB) angioplasty according to neointimal characteristics. This study investigated long-term clinical outcomes according to timing of in-stent restenosis (ISR) and neointimal characteristics in patients with drug-eluting stent (DES) ISR after DCB angioplasty.

METHODS AND

RESULTS

In all, 122 patients (122 ISR lesions), treated with DCB under optical coherence tomography (OCT) examination before and after DCB, were categorized as early ISR (<12 months; E-ISR; n=21) and late ISR (≥12 months; L-ISR; n=101). Associations between OCT-based neointima characteristics and period of ISR, as well as clinical outcomes after DCB were evaluated. Major adverse cardiac events (MACE) were a composite of cardiac death, non-fatal myocardial infarction, or target lesion revascularization (TLR). Quantitative parameters of the neointima were similar, but qualitative characteristics showed significant differences between the E-ISR and L-ISR groups. The incidence of MACE (33.3% vs. 20.8%; P=0.069) and TLR (33.3% vs. 18.5%; P=0.040) was higher in the E-ISR group. In addition, the incidence of MACE was significantly higher for heterogeneous than non-heterogeneous neointima (43.7% vs. 19.6%; P=0.018), but was not significantly associated with neoatherosclerosis (33.4% vs. 18.4%; P=0.168).

CONCLUSIONS

DCB angioplasty is less effective for heterogeneous neointima in DES ISR. OCT-based neointimal evaluation may be helpful in guiding treatment of DES ISR.

Для цитирования: Lee Jung-Hee, Jung Hae Won, Kim Jung-Sun, Hong Sung-Jin, Ahn Chul-Min, Kim Byeong-Keuk, Ko Young-Guk, Choi Donghoon, Hong Myeong-Ki, Jang Yangsoo. Different Neointimal Pattern in Early vs. Late In-Stent Restenosis and Clinical Outcomes After Drug-Coated Balloon Angioplasty - An Optical Coherence Tomography Study.. Circulation journal : official journal of the Japanese Circulation Society. 2018. DOI: 10.1253/circj.cj-18-0619.