MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11748-023-01984-x

Медицинская библиотека · General thoracic and cardiovascular surgery · 2023

Hemodynamic predictors of negative false lumen remodeling after frozen elephant trunk for acute aortic dissection.

Takei Yusuke, Miyazaki Shohei, Suzuki Kohei, Saito Shunsuke, Oogaki Hayato, Muraoka Yuki, Ogasawara Takeshi, Tezuka Masahiro, Shibasaki Ikuko, Fukuda Hirotsugu

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

We evaluated the blood flow within the downstream aortic false lumen after frozen elephant trunk repair for acute aortic dissection and identified hemodynamic predictors of false lumen expansion and negative false lumen remodeling using four-dimensional flow magnetic resonance imaging.

METHODS

Thirty-one patients (Stanford type A, n = 28; Stanford type B, n = 3) with patent false lumen who underwent frozen elephant trunk procedures for acute aortic dissection were included in this observational study. Each patient underwent computed tomography during the follow-up period and four-dimensional flow magnetic resonance imaging within 3 postoperative months. The false lumen volumetric expansion rate was calculated using computed tomography data. The direction and the rate of flow in the lower descending aortic false lumen were analyzed. Negative false lumen remodeling was defined as a volumetric increase of > 10% from the baseline volume.

RESULTS

Negative false lumen remodeling had developed in 6 of the 31 patients during the observation period. Most of the false lumen flows were biphasic during systole. The range between peak and nadir flow rates was associated with the false lumen volumetric expansion rate (β coefficient = 6.77; p < 0.01, R2 = 0.43).

CONCLUSIONS

The range between peak and nadir flow rates may serve as a hemodynamic predictor of negative false lumen remodeling, enabling further treatment for patients at risk of expansion in the downstream aorta.

Для цитирования: Takei Yusuke, Miyazaki Shohei, Suzuki Kohei, Saito Shunsuke, Oogaki Hayato, Muraoka Yuki, Ogasawara Takeshi, Tezuka Masahiro, Shibasaki Ikuko, Fukuda Hirotsugu. Hemodynamic predictors of negative false lumen remodeling after frozen elephant trunk for acute aortic dissection.. General thoracic and cardiovascular surgery. 2023. DOI: 10.1007/s11748-023-01984-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.