Diagnostic potential of soluble ST2 and D-dimer for Stanford Type B aortic dissection and intramural aortic hematoma.

Zhu Qian, Wang Lei, Dai Chao, Zhang Yonghua, Han Pengpeng, Huang Yongxiang, Liu Huan, Wang Lixin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Type B aortic dissection (TBAD) and intramural aortic hematoma (IMH) are common manifestations of Acute Aortic Syndrome (AAS), exhibiting overlapping clinical features. The timely and accurate diagnosis and differentiation between TBAD and IMH are critical for appropriate management. Tumorigenicity 2 (sST2) and D-dimer have been shown to elevate levels in both TBAD and IMH, making them valuable as "rule-out" markers. Hence, we aimed to assess the diagnostic utility of sST2 and D-dimer in distinguishing TBAD from IMH.

METHODS

In this retrospective study, we analyzed serum levels of sST2 and D-dimer in 182 AAS patients, comprising 90 TBAD cases, 92 IMH cases, and 90 non-AAS cases. Serial measurements were taken at 1 h, 6 h, 12 h, 24 h, and 72 h post-admission. Comparative analyses were conducted between TBAD and non-AAS cases, IMH and non-AAS cases, and TBAD and IMH cases. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic accuracy of sST2 and D-dimer in identifying TBAD or IMH cases.

RESULTS

Both TBAD and IMH patients displayed elevated levels of sST2 and D-dimer compared to non-AAS cases. Notably, sST2 levels were significantly higher in TBAD patients than in IMH patients, whereas D-dimer levels exhibited moderate differences. TBAD patients tended to exhibit elevated levels of either sST2 or D-dimer, with a modest correlation between the two (Pearson correlation coefficient = 0.3614). In contrast, IMH patients showed elevations in both markers, with a positive correlation between them (Pearson correlation coefficient = 0.6814). The ROC analysis revealed that both sST2 (AUC, 0.657; 95 % CI, 0.552-0.753; cutoff value, 27.54 ng/ml) and D-dimer (AUC, 0.695; 95 % CI, 0.591-0.787, cutoff value, 1.215 ng/ml) demonstrated favorable diagnostic performance for TBAD. sST2 exhibited a sensitivity of 80.92 % and a specificity of 75.00 %, while D-dimer showed a sensitivity of 80.92 % and a specificity of 75.00 %. For the diagnosis of IMH, the combined assessment of sST2 and D-dimer (AUC, 0.674; 95 % CI, 0.599-0.768; sensitivity, 69.20 %; specificity, 80.00 %) proved effective.

CONCLUSIONS

Our results indicate that both sST2 and D-dimer show diagnostic potential for TBAD. Elevated levels of either serve as an indicator of TBAD onset. However, concurrent elevation of both markers seems to be indicative of IMH. The combination of increased sST2 and D-dimer levels demonstrates strong diagnostic performance in identifying IMH cases.

Для цитирования: Zhu Qian, Wang Lei, Dai Chao, Zhang Yonghua, Han Pengpeng, Huang Yongxiang, Liu Huan, Wang Lixin. Diagnostic potential of soluble ST2 and D-dimer for Stanford Type B aortic dissection and intramural aortic hematoma.. Microvascular research. 2023. DOI: 10.1016/j.mvr.2023.104623.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.