DOI 10.1016/j.cjca.2023.09.034
The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear.
Аннотация
BACKGROUND
A distal anastomotic new entry tear (DANE) can occur at the time of surgical repair for acute type A aortic dissection (ATAAD). This study aimed to compare the occurrence of DANE following a standard hemiarch repair with that following a hemiarch repair with an uncovered arch dissection stent.
METHODS
All patients who received a hemiarch repair or a hemiarch repair with an Ascyrus Medical Dissection Stent (AMDS) for ATAAD from 2017 to 2021 were included. Baseline and intra- and postoperative characteristics were collected. All available pre- and postoperative computed tomographic scans were analysed. The primary outcome measures were the incidence of DANE, positive aortic remodelling, mortality, and aortic reintervention rates at last follow-up.
RESULTS
A total of 114 patients underwent repair of Debakey I ATAAD during the study period with either an isolated hemiarch (n = 77) or a hemiarch with AMDS (n = 37). There was no significant difference in mortality (P = 0.768) or other in-hospital adverse events. During the follow-up period, DANE occurred in 43.3% (n = 26) of the isolated hemiarch group and in 11.8% (n = 4) of the hemiarch with AMDS group (P = 0.002). The incidence of false lumen thrombosis and obliteration favoured the AMDS group in the aortic arch (P = 0.029), the proximal descending thoracic aorta (P = 0.031), and level of pulmonary artery bifurcation (P = 0.044).
CONCLUSIONS
The incidence of DANE is significantly reduced with the addition of an AMDS at the time of hemiarch repair for ATAAD repair. Further follow-up is necessary to identify late aortic complications that may have been prevented by reducing the incidence of postoperative DANE.