MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15266028231199930

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2023

The Role of Location, Length, and Thickness of the Intimal Flap in the Propagation of Stanford Type B Aortic Dissection Based on Ex Vivo Porcine Aorta Models.

Wang Shuangjing, Jia Heyue, Xi Yifu, Yuan Pengfei, Wu Mingwei, Guo Wei, Chen Duanduan, Xiong Jiang

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To explore the role of location, length, and thickness of the intimal flap in the propagation of Stanford type B aortic dissection (TBAD) based on ex vivo porcine aorta models based on ex vivo porcine aorta models.

MATERIALS AND

METHODS

The porcine aortas were harvested and randomly divided into 6 groups to create various TBAD aortic models. We constructed intimal flaps for different locations (group A [entry tear on outer curvature] and group B [entry tear on inner curvature]), lengths (group C [long] and group D [short]), and thicknesses (group E [thick] and group F [thin]). For the ex vivo perfusion experiments conducted on model aortas, an experimental circulation loop (ECL) was employed. The pressure in false lumen (FL) was constantly monitored. A comparison was made between the morphological data collected before and after the experiment to quantify the changes in the FL after the experiment.

RESULTS

Compared the results with group B, the mean peak pressures of the FL in group A were lower (106.87±15.55 vs. 124.01±22.75 mm Hg, p=0.028). The mean axial propagation length in group A was shown to be shorter than that of group B (88.14±33.38 vs. 197.43±41.65 mm, p<0.001). The mean peak pressure was higher in group C than in group D (144.04±19.37 vs. 92.51±26.70 mm Hg, p<0.001). The mean peak pressure of group E was higher than that of group F (160.83±32.83 vs. 109.33±15.62 mm Hg, p<0.001), as was the mean axial propagation length of group E (143.11±39.73 vs. 100.45±35.44 mm, p=0.021). According to the results of multivariable linear regression, axial propagation length=45.873-0.703×length of initial FL+0.863× peak pressure (p<0.001).

CONCLUSION

There was a relationship between FL propagation and the location, length, and thickness of the intimal flap. The axial propagation length was related to the length of the intimal flap and the peak pressure of propagation. It may be helpful to evaluate the risk of propagation in patients with TBAD.Clinical ImpactThis study found that the locations, lengths, and thickness of the intimal flap significantly contributed to propagation pressure of FL. Using dissection flap characteristics, a physician can predict FL development in a patient and formulate a treatment plan.The purpose was to investigate the relationship between the dissection flap characteristics (location, length, and thickness) and the propagation of the FL, which is not clear at present. This study employed porcine models to create an experimental circulation loop. The perfusion experiment was conducted using a FL without distal re-entry and a non-pulsating flow.

Для цитирования: Wang Shuangjing, Jia Heyue, Xi Yifu, Yuan Pengfei, Wu Mingwei, Guo Wei, Chen Duanduan, Xiong Jiang. The Role of Location, Length, and Thickness of the Intimal Flap in the Propagation of Stanford Type B Aortic Dissection Based on Ex Vivo Porcine Aorta Models.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2023. DOI: 10.1177/15266028231199930.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.