MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1552-6569.2012.00769.x

Медицинская библиотека · Journal of neuroimaging : official journal of the American Society of Neuroimaging · 2012

Azygous anterior cerebral artery and associated aneurysms: detection and identification using 3-dimensional time-of-flight magnetic resonance angiography.

Wan-Yin Shi, Ming-Hua Li, Bin-Xian Gu, Yong-Dong Li, Hua-Qiao Tan

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: The azygous anterior cerebral artery (Az) is a rarely observed anomaly of the anterior cerebral artery, and its associated aneurysm is even rarer. Our aim was to evaluate 3-dimensional time-of-flight magnetic resonance angiography (3-D-TOF MRA) in the diagnosis of Az and associated aneurysms.

MATERIALS AND

METHODS

Three thousand five hundred seventy-two consecutive patients underwent 3-D-TOF MRA at 3.0 T. Postprocessing techniques, including volume rendering (VR) and single artery highlighting, were performed by a 3-D specialist. All MRA data and clinical information were recorded and stored in a database for further analysis.

RESULTS

Fourteen patients (.39%) were identified as having an Az. Among these cases, 3 males (21.43%) had an aneurysm located at the distal bifurcation of the Az, with a mean size of 9.43 ± 3.33 mm. In MRA, the common trunk of the Az was slightly larger in diameter than the A1 segment (2.62 ± .35 mm vs. 2.54 ± .35 mm; P = .008).

CONCLUSIONS

With the VR technique, 3-D-TOF MRA is feasible and valuable in detecting an Az and associated aneurysm. Our MRA-based study has proved that the Az is a rare anomaly but has a relatively high incidence of associated aneurysms.

Для цитирования: Wan-Yin Shi, Ming-Hua Li, Bin-Xian Gu, Yong-Dong Li, Hua-Qiao Tan. Azygous anterior cerebral artery and associated aneurysms: detection and identification using 3-dimensional time-of-flight magnetic resonance angiography.. Journal of neuroimaging : official journal of the American Society of Neuroimaging. 2012. DOI: 10.1111/j.1552-6569.2012.00769.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.