MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jccase.2017.07.009

Медицинская библиотека · Journal of cardiology cases · 2017

An autopsy case of aortic root rupture with thin porcelain aorta during balloon-expandable transcatheter aortic valve implantation.

Suzuyama Hiroto, Sakamoto Tomohiro, Konami Yutaka, Taguchi Eiji, Horibata Yoko, Nishigami Kazuhiro, Nakao Koichi, Kamio Takihiro, Ideta Ichiro, Uesugi Hideyuki, Murakami Koutaro, Haratake Yoshikazu

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

A 92-year-old woman was transferred to our institute due to drug-resistant heart failure from severe aortic stenosis. She seemed to be a candidate for transcatheter aortic valve implantation (TAVI) because of her frailty and porcelain aorta. There were no severe calcified nodules in the left-ventricular outflow tract area. Because three-dimensional computed tomography analysis showed that her basal annulus area was 419 mm2, a 26-mm SAPIEN XT (Edwards Lifesciences, Irvine, CA, USA) was selected for implantation. After deployment of the valve with 10% reduced volume, aortic root rupture occurred and her blood pressure fell due to acute cardiac tamponade. Emergent cardiac pericardial fenestration was done and drained blood was continuously returned to the circulation through percutaneous cardiopulmonary bypass. Despite strenuous efforts to save her life, she died 13 h after the event. An autopsy revealed a thin porcelain aorta and aortic root rupture with a fragile aortic wall. <Learning objective: Porcelain aorta is known to be a risk factor for perioperative stroke during surgical aortic valve replacement, and TAVI could be chosen for a treatment strategy in those cases. We present a case of aortic root rupture caused by unusually fragile aortic wall during TAVI and the lesson from the autopsy results.>.

Для цитирования: Suzuyama Hiroto, Sakamoto Tomohiro, Konami Yutaka, Taguchi Eiji, Horibata Yoko, Nishigami Kazuhiro, Nakao Koichi, Kamio Takihiro, Ideta Ichiro, Uesugi Hideyuki, Murakami Koutaro, Haratake Yoshikazu. An autopsy case of aortic root rupture with thin porcelain aorta during balloon-expandable transcatheter aortic valve implantation.. Journal of cardiology cases. 2017. DOI: 10.1016/j.jccase.2017.07.009.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.