BACKGROUND

Aim of our study is the analysis of clinical results and aneurysmal sac evolution after multilayer flow modulator (MFM) placement, in patients with thoracoabdominal aortic aneurysms (TAAs).

METHODS

All patients with asymptomatic TAA treated at our institution between 2012 and 2014 with MFM were retrospectively analyzed. Thirty-day evaluated outcomes were mortality and complications. Follow-up evaluated outcomes were mortality, aneurysm collateral branches patency, and reintervention. A geometrical analysis of 2-year follow-up computed tomography scans was carried out to evaluate the total aneurysm volume, the percentage of aneurysm growth, and the evolution of maximum aneurysm diameter.

RESULTS

Seven patients (mean age: 71.8 years, range: 63-85 years) were considered in the study. Mean preoperative aneurysm diameter was 6.8 cm (range 6-8.3 cm). No 30-day mortality or complications were observed. Mean follow-up was 29.4 months. During follow-up, 3 deaths (42.8%) were observed, not related to MFM complications. Reintervention rate was 42.8%, occurred in all cases after 2-year follow-up; in 2 cases, the reintervention was necessary due to an excessive increase of the aneurysmal sac. During the follow-up, a mean growth rate of 6 mm/year (4 patients) for the diameter of the aneurysm external wall and a total aneurysm volume increase from 2.45 × 105 mm3 to 3.50 × 105 mm3 (4 patients) was evaluated.

CONCLUSIONS

Our results have shown no mortality related to aneurysm rupture during the follow-up and high rate of reinterventions after MFM placement. Further geometrical analyses, based on the proposed approach, regarding a larger group of patients with long-term follow-up are required to draw indications about the MFM use.

Для цитирования: Spinella Giovanni, Finotello Alice, Faggiano Elena, Pane Bianca, Conti Michele, Gazzola Valerio, Auricchio Ferdinando, Palombo Domenico. Midterm Follow-up Geometrical Analysis of Thoracoabdominal Aortic Aneurysms Treated with Multilayer Flow Modulator.. Annals of vascular surgery. 2018. DOI: 10.1016/j.avsg.2018.04.034.