m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2019

One-Year Follow-Up of Conduction Abnormalities After Transcatheter Aortic Valve Implantation With the SAPIEN 3 Valve.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dolci Giulia, Vollema E Mara, van der Kley Frank, de Weger Arend, Ajmone Marsan Nina, Delgado Victoria, Bax Jeroen J

Аннотация

Long-term evolution of new-onset conduction abnormalities and need of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) have not been extensively evaluated. We describe the incidence and time course of new conduction abnormalities and the rate of PPI with the new-generation transcatheter aortic valve prosthesis Edwards SAPIEN 3 (S3). In total, 266 patients with severe aortic stenosis who underwent TAVI were retrospectively analyzed. Twelve-lead electrocardiograms at baseline, after TAVI, at discharge, at 1-, 6-, and 12-month follow-up were evaluated to identify conduction abnormalities and PPI requirements to investigate the correlates of PPI. After TAVI, a significant increase in PR interval duration and in QRS complex width was observed. New-onset left bundle branch block was observed in 65 patients (24%) after TAVI. The number of patients with left bundle branch block was maximum at hospital discharge and decreased at 12-month follow-up (39% and 32%, respectively). Thirty-five patients (13%) required PPI during the follow-up. However, paced rhythm was only observed in 7% of the patients with a complete 12-month follow-up. Patients who underwent PPI had a higher prevalence of first-degree atrioventricular block, complete right bundle branch block, and wider QRS complex at baseline. Baseline right bundle branch block and QRS width immediately after TAVI were the only variables independently associated with PPI. In conclusion, conduction disorders have a temporary nature after TAVI and showed a trend toward stabilization during the following months. With this new-generation device, the incidence of new conduction abnormalities requiring PPI is relatively low.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты