MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjps.2009.09.021

Медицинская библиотека · Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2009

Multidetector-row computed tomography (MDCT) analysis of the supra-fascial perforator directionality (SPD) of the occipital artery perforator (OAP).

Ono Shimpei, Ogawa Rei, Hayashi Hiromitsu, Takami Yoshihiro, Kumita Shin-Ichiro, Hyakusoku Hiko

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The occipital artery (OA) has three major cutaneous branches, all of which can be used to make occipital artery perforator (OAP) flaps on the posterior scalp and nape. To optimise OAP flap design, it is important to determine the supra-fascial perforator directionality (SPD) of the three branches.

MATERIALS AND

METHODS

We analysed the anatomical characteristics of the OAP by using the stored Digital Imaging and Communications (DICOM) multidetector-row CT (MDCT) data of 10 cases. For all cases, the branches arising from the OAP were counted and their origins and courses were traced on the computer. Branch diameters and lengths, and the distance between branch origin and the occipital protuberance or mastoid process, were measured. Averages were calculated.

RESULTS

All cases had three OAP branches, namely an ascending, a transverse and a descending branch (the average branch number was 3.2±0.4). Their average vessel diameters were 16.8, 10.8 and 10.0mm, respectively. Their average SPD lengths were 71.1, 20.8 and 21.6mm, respectively. After the OA penetrated the fascia (thus becoming the OAP), the descending branch arose from the OAP within 10mm of the piercing point and travelled downwards and inwards. Above the descending branch bifurcation point, the OAP divided into the transverse branch, which travelled upwards and inwards, and the ascending branch, which travelled upwards.

CONCLUSIONS

The OAP has three branches, all of which can be reliable vascular pedicles for scalp and nape skin flaps. Knowing the SPD of each branch is important for designing flap shape.

Для цитирования: Ono Shimpei, Ogawa Rei, Hayashi Hiromitsu, Takami Yoshihiro, Kumita Shin-Ichiro, Hyakusoku Hiko. Multidetector-row computed tomography (MDCT) analysis of the supra-fascial perforator directionality (SPD) of the occipital artery perforator (OAP).. Journal of plastic, reconstructive & aesthetic surgery : JPRAS. 2009. DOI: 10.1016/j.bjps.2009.09.021.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.