MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tmi.2011.2170847

Медицинская библиотека · IEEE transactions on medical imaging · 2011

High range resolution ultrasonographic vascular imaging using frequency domain interferometry with the Capon method.

Taki Hirofumi, Taki Kousuke, Sakamoto Takuya, Yamakawa Makoto, Shiina Tsuyoshi, Kudo Motoi, Sato Toru

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

For high range resolution ultrasonographic vascular imaging, we apply frequency domain interferometry with the Capon method to a single frame of in-phase and quadrature (IQ) data acquired using a commercial ultrasonographic device with a 7.5 MHz linear array probe. In order to tailor the adaptive beam forming algorithm for ultrasonography we employ four techniques: frequency averaging, whitening, radio-frequency data oversampling, and the moving average. The proposed method had a range resolution of 0.05 mm in an ideal condition, and experimentally detected the boundary couple 0.17 mm apart, where the boundary couple was indistinguishable from a single boundary utilizing a B-mode image. Further, this algorithm could depict a swine femoral artery with a range beam width of 0.054 mm and an estimation error for the vessel wall thickness of 0.009 mm, whereas using a conventional method the range beam width and estimation error were 0.182 and 0.021 mm, respectively. The proposed method requires 7.7 s on a mobile PC with a single CPU for a 1×3 cm region of interest. These findings indicate the potential of the proposed method for the improvement of range resolution in ultrasonography without deterioration in temporal resolution, resulting in enhanced detection of vessel stenosis.

Для цитирования: Taki Hirofumi, Taki Kousuke, Sakamoto Takuya, Yamakawa Makoto, Shiina Tsuyoshi, Kudo Motoi, Sato Toru. High range resolution ultrasonographic vascular imaging using frequency domain interferometry with the Capon method.. IEEE transactions on medical imaging. 2011. DOI: 10.1109/tmi.2011.2170847.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.