MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mp.17615

Медицинская библиотека · Medical physics · 2025

Breast radiation therapy fluence painting with multi-agent deep reinforcement learning.

Dongrong Yang, Xinyi Li, Sua Yoo, Rachel Blitzblau, Susan McDuff, Sarah Stephens, Paul Segars, Q Jackie Wu, Yang Sheng

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The electronic compensation (ECOMP) technique for breast radiation therapy provides excellent dose conformity and homogeneity. However, the manual fluence painting process presents a challenge for efficient clinical operation.

PURPOSE: To facilitate the clinical treatment planning automation of breast radiation therapy, we utilized reinforcement learning (RL) to develop an auto-planning tool that iteratively edits the fluence maps under the guidance of clinically relevant objectives.

METHODS

With institutional review board (IRB) approval, 70 patients treated with 6MV tangential photon beams with ECOMP technique were retrospectively collected and included in this study (20/50 for training/testing). Each pixel in the fluence map was assigned a reinforcement learning agent to perform independent action. Beam-eye-view projected dose profiles were generated to form state information as the input of the RL network. By predicting the Q value, pixel-wise actions were selected to modify specific pixel value in the fluence maps to improve overall plan quality. After dose calculation, reward signal calculated from the variation of target coverage and dose homogeneity was fed back to the RL framework and used to update network parameters. The RL generated plans were evaluated with dose distribution and dosimetric endpoints (i.e., Breast PTV V90%, Breast PTV V95%, Breast PTV V105%, Lung V20 Gy, Heart V5 Gy, Dmax) and compared with clinical plans.

RESULTS

The RL agent took around 90 s to generate a ECOMP treatment plan. The RL plans exhibited plan quality comparable to clinical plans in terms of isodose distribution and dosimetric endpoints. The mean Breast PTV V95%, Breast PTV V105% of RL plans are 77.759 % ( ± 8.904 % ) $77.759{\mathrm{\ \% }}( { \pm 8.904{\mathrm{\ \% }}} )$ and 8.522 cc ( ± 11.469 cc ) $8.522{\mathrm{\ cc\ }}( { \pm 11.469{\mathrm{\ cc}}} )$ , compared to 78.568 % ( ± 9.094 % ) $78.568{\mathrm{\ \% }}( { \pm 9.094{\mathrm{\ \% }}} )$ and 34.298 cc ( ± 36.297 cc ) $34.298\ {\mathrm{cc}}\ ( { \pm 36.297{\mathrm{\ cc}}} )$ cc of clinical plans.

CONCLUSION

The developed RL framework efficiently generates breast ECOMP plans with clinical acceptable plan quality.

Для цитирования: Dongrong Yang, Xinyi Li, Sua Yoo, Rachel Blitzblau, Susan McDuff, Sarah Stephens, Paul Segars, Q Jackie Wu, Yang Sheng. Breast radiation therapy fluence painting with multi-agent deep reinforcement learning.. Medical physics. 2025. DOI: 10.1002/mp.17615.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.