DOI 10.1016/j.acra.2024.11.014
Accuracy of Radiomics in the Identification of Extrathyroidal Extension and BRAFV600E Mutations in Papillary Thyroid Carcinoma: A Systematic Review and Meta-analysis.
Аннотация
RATIONALE AND
OBJECTIVES
Extrathyroidal extension (ETE) and BRAFV600E mutation in papillary thyroid cancer (PTC) increase mortality and recurrence risk. Preoperative identification presents considerable challenges. Although radiomics has emerged as a potential tool for identifying ETE and BRAFV600E mutation, systematic evidence supporting its effectiveness remains insufficient. Therefore, this paper aims to determine the effectiveness of radiomics in detecting ETE and BRAFV600E mutations in PTC.
MATERIALS AND
METHODS
PubMed, Web of Science, Cochrane, and Embase databases were searched until May 7th, 2024. The Radiomics Quality Score tool assessed bias risk. Subgroup analyses based on radiomics and clinical characteristics were conducted.
RESULTS
Our systematic review included 19 studies, encompassing 5337 PTC cases. Among these, 12 articles focused on ETE and seven articles focused on BRAFV600E mutations. For the identification of ETE in the validation set, the summarized machine learning (ML) models demonstrated 0.80c-index (95%CI: 0.77-0.83), 0.77 sensitivity (95%CI: 0.72-0.81), and 0.78 specificity (95%CI: 0.73-0.82). Radiomics based on ultrasound demonstrated 0.82c-index (95%CI: 0.78-0.86), 0.77 sensitivity (95%CI: 0.68-0.84), and 0.84 specificity (95%CI: 0.75-0.91). For the identification of BRAFV600E mutations in the validation set, the summarized ML models showed 0.80c-index (95%CI: 0.72-0.87), 0.76 sensitivity (95%CI: 0.67-0.84), and 0.88 specificity (95%CI: 0.77-0.94). ML models based on ultrasound-guided radiomics had 0.81c-index (95%CI: 0.74-0.89), 0.79 sensitivity (95%CI: 0.71-0.86), and 0.87 specificity (95%CI: 0.74-0.94).
CONCLUSION
Radiomics in identifying ETE and BRAFV600E mutation have high c-index, sensitivity, and specificity, especially images from ultrasound, demonstrating the potential for diagnosing ETE and BRAFV600E mutations in PTC.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.