MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circep.119.007150

Медицинская библиотека · Circulation. Arrhythmia and electrophysiology · 2019

Familial Clustering of Cardiac Conduction Defects and Pacemaker Insertion.

Kaess Bernhard M, Andersson Charlotte, Duncan Meredith S, Larson Martin G, Aasbjerg Kristian, Gislason Gunnar H, Torp-Pedersen Christian, Vasan Ramachandran S

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The etiopathogenesis of electrocardiographic bundle branch and atrioventricular blocks is not fully understood. We investigated familial clustering of cardiac conduction defects and pacemaker insertion in the FHS (Framingham Heart Study). Additionally, we assessed familial clustering of pacemaker insertion in the Danish general population.

METHODS

In FHS, we used multivariable-adjusted logistic regression models to investigate the association of parental atrioventricular block (PR interval, ≥0.2 s), complete bundle branch block (QRS, ≥0.12 s), or pacemaker insertion with the occurrence of cardiac conduction abnormalities in their offspring. The Danish nationwide administrative registries were interrogated to assess the relations of parental pacemaker insertion with offspring pacemaker insertion.

RESULTS

In FHS (n=371 cases with first-degree atrioventricular block, complete bundle branch block, or pacemaker insertion, and 1471 age- and sex-matched controls), individuals with at least 1 affected parent with a conduction defect had a 1.65-fold odds (odds ratio, 95% CI, 1.32-2.07) for manifesting an atrioventricular block and a 1.62-fold odds (95% CI, 1.08-2.42) for developing a complete bundle branch block. If at least 1 parent had any electrocardiographic conduction defect or pacemaker insertion, the offspring had a 1.62-fold odds (95% CI, 1.31-2.00) for experiencing any of these conditions. In Denmark (n=2 824 199 individuals; 5397 incident pacemaker implantations), individuals with at least 1 first-degree relative with history of pacemaker insertion had a multivariable-adjusted 1.68-fold (incidence rate ratio, 95% CI, 1.49-1.89) risk of undergoing a pacemaker insertion. If the affected relative was ≤45 years of age, the incidence rate ratio was markedly increased to 51.0 (95% CI, 32.7-79.9).

CONCLUSIONS

Cardiac conduction blocks and risk for pacemaker insertion cluster within families. A family history of conduction system disturbance or pacemaker insertion should trigger increased awareness of a similar propensity in other family members, especially so when the conduction system disease occurs at a younger age.

Для цитирования: Kaess Bernhard M, Andersson Charlotte, Duncan Meredith S, Larson Martin G, Aasbjerg Kristian, Gislason Gunnar H, Torp-Pedersen Christian, Vasan Ramachandran S. Familial Clustering of Cardiac Conduction Defects and Pacemaker Insertion.. Circulation. Arrhythmia and electrophysiology. 2019. DOI: 10.1161/circep.119.007150.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.