DOI 10.1177/15533506251374470

Медицинская библиотека · Surgical innovation · 2025

Optimized 'Full Right' Instrument Configuration in Robotic Rectal Surgery With the Da Vinci Xi System: A Prospective Single-Center Experience.

Monsellato Igor, Gatto Teresa, Palucci Marco, Sangiuolo Federico, Alagia Mariantonietta, Giannone Fabio, Cassese Gianluca, Del Basso Celeste, Del Angel-Millán Gabriela, Panaro Fabrizio

СтатьяПеревод пока не подготовлен

Аннотация

BackgroundRobotic surgery for rectal cancer offers enhanced visualization, instrument articulation, and ergonomic benefits in confined pelvic spaces. However, the effectiveness of robotic procedures depends heavily on trocar positioning and instrument layout. Conventional configurations often require intraoperative instrument swapping or camera repositioning, potentially disrupting workflow and increasing cognitive strain. To address these limitations, we implemented a standardized "full right" instrument configuration using the Da Vinci Xi system to improve ergonomic control and procedural stability.MethodsWe conducted a prospective analysis of 22 consecutive patients undergoing robotic rectal resection at a high-volume tertiary center using the full right configuration. All robotic arms and the assistant port were positioned along the patient's right side, with the camera fixed on Arm 2 throughout the procedure. Operative, perioperative, and pathological outcomes were evaluated.ResultsThe mean console time was 170 min, and the mean operative time was 192 min. No conversions or intraoperative complications occurred. No instrument collisions were observed. Estimated blood loss was minimal in all cases. The mean hospital stay was 5.2 days. All patients achieved complete (grade 3) mesorectal excision, with a mean lymph node yield of 16.4 and negative margins in every case. No major postoperative complications were reported.ConclusionsThe full right configuration for robotic rectal resection is associated with favorable short-term outcomes, improved ergonomic conditions, and stable instrument positioning. This layout supports consistent workflow across all operative phases and may reduce intraoperative cognitive load. Further validation through larger comparative studies is warranted.

Для цитирования: Monsellato Igor, Gatto Teresa, Palucci Marco, Sangiuolo Federico, Alagia Mariantonietta, Giannone Fabio, Cassese Gianluca, Del Basso Celeste, Del Angel-Millán Gabriela, Panaro Fabrizio. Optimized 'Full Right' Instrument Configuration in Robotic Rectal Surgery With the Da Vinci Xi System: A Prospective Single-Center Experience.. Surgical innovation. 2025. DOI: 10.1177/15533506251374470.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.