MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0257283

Медицинская библиотека · PloS one · 2021

The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided caudal block in anorectal surgery. A dose finding study.

Li Xuehan, Li Jun, Zhang Pei, Deng Huifei, Yang Mingan, He Hongbo, Wang Rurong

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Caudal epidural block (CEB) provides reliable anesthesia for adults undergoing anorectal surgery. Despite the widely utilization, the minimum effective concentration for 90% patients (MEC90) of ropivacaine for CEB remains unknown.

OBJECTIVE

To estimate MEC of ropivacaine for CEB in anorectal surgery.

DESIGN

A prospective dose-finding study using biased coin design up-and-down sequential method.

SETTING

Operating room and postoperative recovery area of Chengdu Shangjin Nanfu Hospital, from October 2019 to January 2020.

PATIENTS: 50 males and 51 females scheduled for anorectal surgery.

INTERVENTIONS: We conducted two independent biased coin design up-and down trials by genders. The concentration of ropivacaine administered to the first patient of male and female were 0.25% with fixed volume of 14ml for male and 12ml for female patients based on our previous study. In case of failure, the concentration was increased by 0.05% in the next subject. Otherwise, the next subject was randomized to a concentration 0.05% less with a probability of 0.11, or the same concentration with a probability of 0.89. Success was defined as complete sensory blockade of perineal area 15 min after the block evidenced by the presence of a lax anal sphincter and pain-free surgery.

MAIN OUTCOME MEASURES: The MEC of ropivacaine to achieve a successful CEB in 90%(MEC90) of the patients.

RESULTS

The MEC90 of ropivacaine for CEB were estimated to be 0.35% (95% CI 0.29 to 0.4%) for male and 0.353% (95%CI 0.22 to 0.4%) for female. By extrapolation to MEC in 99% of subjects (MEC99) and pooled adjacent violators algorithm (PAVA) adjusted responses, it would be optimal to choose 0.4% ropivacaine with a volume of 14ml for male and 12ml for female.

CONCLUSIONS

A concentration of 0.35% ropivacaine with a volume of 14ml provided a successful CEB in 90% of the male patients, while 0.353% ropivacaine with a volume of 12ml provided a successful CEB in 90% of the female patients. A concentration of 0.4% and a volume of 14ml for male and 12 ml for female would be successful in 99% of the patients.

TRIAL REGISTRATION: Chictr.org.cn identifier: No. ChiCTR 1900024315.

Для цитирования: Li Xuehan, Li Jun, Zhang Pei, Deng Huifei, Yang Mingan, He Hongbo, Wang Rurong. The minimum effective concentration (MEC90) of ropivacaine for ultrasound-guided caudal block in anorectal surgery. A dose finding study.. PloS one. 2021. DOI: 10.1371/journal.pone.0257283.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.