MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The American journal of gastroenterology · 1995

Relationship between directly measured portal pressure gradient and variceal hemorrhage.

Jalan R, Redhead D N, Forrest E H, Hayes P C

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

It is commonly believed that variceal hemorrhage in patients with cirrhosis and portal hypertension does not occur below a portal pressure gradient (PPG) of 12 mm Hg. The aim of this study was to assess the relationship between directly measured portal pressure gradient and variceal hemorrhage.

METHODS

The procedure of insertion of the transjugular intrahepatic portosystemic stent-shunt (TIPSS) for variceal hemorrhage provides access to the portal vein and allows direct measurement of the portal pressure. Right atrial, inferior vena caval, and portal pressure were recorded, and the PPG was calculated (portal pressure-inferior vena caval pressure) in 48 patients undergoing TIPSS for variceal hemorrhage.

RESULTS

PPG was reduced from a mean of 21.4 (6.4) before TIPSS to 10.6 (3.1) mm Hg after the procedure. Seven patients (14.7%) had a baseline portal pressure gradient of < 12 mm Hg.

CONCLUSION

The results of this study do not support the concept of a discrete bleeding threshold.

Для цитирования: Jalan R, Redhead D N, Forrest E H, Hayes P C. Relationship between directly measured portal pressure gradient and variceal hemorrhage.. The American journal of gastroenterology. 1995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.