MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5469/neuroint.2011.6.1.13

Медицинская библиотека · Neurointervention · 2011

Computational flow dynamics of the severe m1 stenosis before and after stenting.

Suh Dae Chul, Ko Young Bae, Park Sung-Tae, Yoon Kyunghwan, Lim Ok Kyun, Oh Jin Sun, Jeong Yun Gyeong, Kim Jong Sung

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Computational flow dynamic (CFD) study has not been widely applied in intracranial artery stenosis due to requirement of high resolution in identifying the small intracranial artery. We described a process in CFD study applied to symptomatic severe intracranial (M1) stenosis before and after stenting.

MATERIALS AND

METHODS

Reconstructed 3D angiography in STL format was transferred to Magics (Materialise NV, Leuven, Belgium) for smoothing of vessel surface and trimming of branch vessels and to HyperMesh (Altair Engineering Inc., Auckland, New Zealand) for generating tetra volume mesh from triangular surface-meshed 3D angiogram. Computational analysis of blood flow in the blood vessels was performed using the commercial finite element software ADINA Ver 8.5 (ADINA R & D, Inc., Lebanon, MA). The distribution of wall shear stress (WSS), peak velocity and pressure in a patient was analyzed before and after intracranial stenting.

RESULTS

Computer simulation of wall shear stress, flow velocity and wall pressure before and after stenting could be demonstrated three dimensionally by video mode according to flow vs. time dimension. Such flow model was well correlated with angiographic finding related to maximum degree of stenosis. Change of WSS, peak velocity and pressure at the severe stenosis was demonstrated before and after stenting. There was no WSS after stenting in case without residual stenosis.

CONCLUSION

Our study revealed that CFD analysis before and after intracranial stenting was feasible despite of limited vessel wall dimension and could reveal change of WSS as well as flow velocity and wall pressure.

Для цитирования: Suh Dae Chul, Ko Young Bae, Park Sung-Tae, Yoon Kyunghwan, Lim Ok Kyun, Oh Jin Sun, Jeong Yun Gyeong, Kim Jong Sung. Computational flow dynamics of the severe m1 stenosis before and after stenting.. Neurointervention. 2011. DOI: 10.5469/neuroint.2011.6.1.13.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.