m+Medelevator.RU
← Поиск публикаций
Journal of voice : official journal of the Voice Foundation · 2024

Virtual Reality-Enhanced Assessment of the Anterior Glottic Angle Using Cadaveric Models: A Proof-of-Concept Study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yogev David, Madgar Ory, Goldberg Tomer, Parmet Yisrael, Guranda Larisa, Havazelet Shany, Vazgovsky Oliana, Tejman-Yarden Shai, Primov-Fever Adi

Аннотация

OBJECTIVES: Vocal fold paralysis (VFP) is a complex disorder that affects voice, speech, swallowing, and overall quality of life. Current evaluation methods for determining the position of paralyzed vocal folds lack the objectivity required for personalized interventions and research on innovative treatments for VFP. This study was designed to validate the accuracy and reproducibility of a virtual reality (VR)-based platform to measure the anterior glottic angle (AGA), a critical component in determining the position of a paralyzed vocal fold.

STUDY DESIGN: Retrospective.

METHODS: A retrospective analysis of computed tomography (CT) scans of 39 adult patients was conducted to measure the AGA shortly after death. Two measurement methods were used: 2-dimensional (2D)-CT for direct measurements on 2D images and a 3-dimensional (3D)-VR method utilizing a dedicated platform to create a 3D VR model of the larynx. The AGA measurements conducted by two senior otolaryngologists using the 3D-VR method were compared to the 2D-CT measurements made by one of these same otolaryngologists.

RESULTS: The mean AGA measured by the 3D-VR method was found to be 32.936 ± 6.486° (n = 39), and the measurements were highly correlated (r = 0.9670, P < 0.0001). By contrast, the 2D-CT method without VR yielded a significantly lower mean angle of 23.754° (n = 35) with a higher standard deviation of 10.365°. The 3D-VR method demonstrated excellent reliability for AGA measurements (intraclass correlation coefficient of 0.954).

CONCLUSION: The findings underscore the potential value of using a VR-based platform to improve reproducibility and reduce the variability in measurements of AGA in cases of VFP.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты