MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chest.2020.04.017

Медицинская библиотека · Chest · 2020

Validation of a Noninvasive Assessment of Pulmonary Gas Exchange During Exercise in Hypoxia.

Howe Connor A, MacLeod David B, Wainman Liisa, Oliver Samuel J, Ainslie Philip N

СтатьяПоддержка исследования: вне правительства СШАВалидационное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Pulmonary gas exchange efficiency, determined by the alveolar-to-arterial Po2 difference (A-aDo2), progressively worsens during exercise at sea-level; this response is further elevated during exercise in hypoxia. Traditionally, pulmonary gas exchange efficiency is assessed through measurements of ventilation and end-tidal gases paired with direct arterial blood gas (ABG) sampling. Because these measures have a number of caveats, particularly invasive blood sampling, the development of new approaches for the noninvasive assessment of pulmonary gas exchange is needed.

RESEARCH QUESTION: Is a noninvasive method of assessing pulmonary gas exchange valid during rest and exercise in acute hypoxia?

STUDY DESIGN AND

METHODS

Twenty-five healthy participants (10 female) completed a staged maximal exercise test on a cycle ergometer in a hypoxic chamber (Fio2 = 0.11). Simultaneous ABGs via a radial arterial catheter and noninvasive gas-exchange measurements (AGM100) were obtained in 2-minute intervals. Noninvasive gas exchange, termed the O2 deficit, was calculated from the difference between the end-tidal and the calculated Pao2 (via pulse oximetry and corrected for the Bohr effect by using the end-tidal Pco2). Noninvasive O2 deficit was compared with the traditional alveolar to arterial oxygen difference (A-aDo2), using the traditional Riley analysis.

RESULTS

Under conditions of rest at room air, hypoxic rest, and hypoxic exercise, strong correlations between the calculated gPao2 and directly measured Pao2 (R2 = 0.97; P < .001; mean bias = 1.70 mm Hg) were observed. At hypoxic rest and exercise, strong relationships between the estimated and directly measured Pao2 (R2 = 0.68; P < .001; mean bias = 1.01 mm Hg) and O2 deficit with the traditional A-aDo2 (R2 = 0.70; P < .001; mean bias = 5.24 mm Hg) remained.

INTERPRETATIONS: Our findings support the use of a noninvasive measure of gas exchange during acute hypoxic exercise in heathy humans. Further studies are required to determine whether this approach can be used clinically as a tool during normoxic exercise in patients with preexisting impairments in gas exchange efficiency.

Для цитирования: Howe Connor A, MacLeod David B, Wainman Liisa, Oliver Samuel J, Ainslie Philip N. Validation of a Noninvasive Assessment of Pulmonary Gas Exchange During Exercise in Hypoxia.. Chest. 2020. DOI: 10.1016/j.chest.2020.04.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.