OBJECTIVE

To examine the extent to which rapid thromboelastography (r-TEG) could decrease the testing time in comparison with that required for kaolin-activated thromboelastography (TEG), and to compare 2 types of blood samples (ie, native and citrated whole blood [WB]), for determining r-TEG values in healthy dogs.

DESIGN

Prospective observational study.

SETTING

University teaching hospital.

ANIMALS: Sixteen healthy Beagles.

INTERVENTIONS: Kaolin-activated TEG test using citrated WB samples and r-TEG test using native and citrated WB samples were performed in 16 dogs. At 60 minutes after the initial blood sampling, further samples were collected from a subset of 6 dogs in the same manner to evaluate intraindividual repeatability of r-TEG.

MEASUREMENTS AND MAIN

RESULTS

The mean time to maximum amplitude (MA) for r-TEG with native and citrated WB samples was recorded as 1313.9 ± 250.9 seconds and 1351.3 ± 264.6 seconds (mean ± SD), respectively, and 1779.9 ± 197.0 seconds for kaolin-activated TEG. Coefficients of variation with native and citrated WB samples for r-TEG values, TEG-activated clotting time, clot formation time, α angle, and MA, were determined to be 13.4% versus 18.8%, 11.1% versus 16.6%, 4.2% versus 5.1%, and 10.0% versus 10.0%, respectively. Intraindividual variations were lower for native WB samples than for citrated WB samples.

CONCLUSIONS

The r-TEG test significantly decreased the mean time to MA compared with the kaolin-activated TEG test. In addition, native WB samples showed lower coefficients of variation and intraindividual variation than citrated WB samples in r-TEG analysis; this suggests that native WB samples can provide more consistent results. Therefore, the r-TEG method using native WB samples is recommended for assessment of dogs' hemostatic status when an early diagnosis is required.

Для цитирования: Wang Hyebin, Nam Aryung, Song Kunho, Youn Hwa Young, Seo Kyoung Won. Comparison of native and citrated whole blood samples for rapid thromboelastography in Beagles.. Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001). 2019. DOI: 10.1111/vec.12907.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.