MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-019-51721-9

Медицинская библиотека · Scientific reports · 2019

Quantification of total haemoglobin concentrations in human whole blood by spectroscopic visible-light optical coherence tomography.

Veenstra Colin, Kruitwagen Saskia, Groener Dafne, Petersen Wilma, Steenbergen Wiendelt, Bosschaart Nienke

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The non-invasive quantification of total haemoglobin concentrations [tHb] is highly desired for the assessment of haematologic disorders in vulnerable patient groups, but invasive blood sampling is still the gold standard in current clinical practice. This work demonstrates the potential of visible-light spectroscopic optical coherence tomography (sOCT) for quantifying the [tHb] in human whole blood. To accurately quantify the [tHb] from the substantial optical attenuation by blood in the visible wavelength range, we used a combination of zero-delay acquisition and focus tracking that ensures optimal system sensitivity at any depth inside the sample. Subsequently, we developed an analysis model to adequately correct for the high scattering contribution by red blood cells to the sOCT signal. We validate our method and compare it to conventional sOCT (without focus tracking and zero-delay acquisition) through ex-vivo measurements on flowing human whole blood, with [tHb] values in the clinical range of 7-23 g/dL. For our method with optimized sensitivity, the measured and expected values correlate well (Pearson correlation coefficient = 0.89, p < 0.01), with a precision of 3.8 g/dL. This is a considerable improvement compared to conventional sOCT (Pearson correlation coefficient = 0.59, p = 0.16; precision of 9.1 g/dL).

Для цитирования: Veenstra Colin, Kruitwagen Saskia, Groener Dafne, Petersen Wilma, Steenbergen Wiendelt, Bosschaart Nienke. Quantification of total haemoglobin concentrations in human whole blood by spectroscopic visible-light optical coherence tomography.. Scientific reports. 2019. DOI: 10.1038/s41598-019-51721-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.