Device complications with addition of defibrillation to cardiac resynchronisation therapy for primary prevention.

Barra Sérgio, Providência Rui, Boveda Serge, Duehmke Rudolf, Narayanan Kumar, Chow Anthony W, Piot Olivier, Klug Didier, Defaye Pascal, Gras Daniel, Deharo Jean-Claude, Milliez Paul, Da Costa Antoine, Mondoly Pierre, Gonzalez-Panizo Jorge, Leclercq Christophe, Heck Patrick, Virdee Munmohan, Sadoul Nicolas, Le Heuzey Jean-Yves, Marijon Eloi

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

In patients indicated for cardiac resynchronisation therapy (CRT), the choice between a CRT-pacemaker (CRT-P) versus defibrillator (CRT-D) remains controversial and indications in this setting have not been well delineated. Apart from inappropriate therapies, which are inherent to the presence of a defibrillator, whether adding defibrillator to CRT in the primary prevention setting impacts risk of other acute and late device-related complications has not been well studied and may bear relevance for device selection.

METHODS

Observational multicentre European cohort study of 3008 consecutive patients with ischaemic or non-ischaemic dilated cardiomyopathy and no history of sustained ventricular arrhythmias, undergoing CRT implantation with (CRT-D, n=1785) or without (CRT-P, n=1223) defibrillator. Using propensity score and competing risk analyses, we assessed the risk of significant device-related complications requiring surgical reintervention. Inappropriate shocks were not considered except those due to lead malfunction requiring lead revision.

RESULTS

Acute complications occurred in 148 patients (4.9%), without significant difference between groups, even after considering potential confounders (OR=1.20, 95% CI 0.72 to 2.00, p=0.47). During a mean follow-up of 41.4±29 months, late complications occurred in 475 patients, giving an annual incidence rate of 26 (95% CI 9 to 43) and 15 (95% CI 6 to 24) per 1000 patient-years in CRT-D and CRT-P patients, respectively. CRT-D was independently associated with increased occurrence of late complications (HR=1.68, 95% CI 1.27 to 2.23, p=0.001). In particular, when compared with CRT-P, CRT-D was associated with an increased risk of device-related infection (HR 2.10, 95% CI 1.18 to 3.45, p=0.004). Acute complications did not predict overall late complications, but predicted device-related infection (HR 2.85, 95% CI 1.71 to 4.56, p<0.001).

CONCLUSIONS

Compared with CRT-P, CRT-D is associated with a similar risk of periprocedural complications but increased risk of long-term complications, mainly infection. This needs to be considered in the decision of implanting CRT with or without a defibrillator.

Для цитирования: Barra Sérgio, Providência Rui, Boveda Serge, Duehmke Rudolf, Narayanan Kumar, Chow Anthony W, Piot Olivier, Klug Didier, Defaye Pascal, Gras Daniel, Deharo Jean-Claude, Milliez Paul, Da Costa Antoine, Mondoly Pierre, Gonzalez-Panizo Jorge, Leclercq Christophe, Heck Patrick, Virdee Munmohan, Sadoul Nicolas, Le Heuzey Jean-Yves, Marijon Eloi. Device complications with addition of defibrillation to cardiac resynchronisation therapy for primary prevention.. Heart (British Cardiac Society). 2018. DOI: 10.1136/heartjnl-2017-312546.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.