MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ejhf.1113

Медицинская библиотека · European journal of heart failure · 2017

Platelet activation is a preoperative risk factor for the development of thromboembolic complications in patients with continuous-flow left ventricular assist device.

Consolo Filippo, Sferrazza Giulia, Motolone Giulia, Contri Rachele, Valerio Lorenzo, Lembo Rosalba, Pozzi Loris, Della Valle Patrizia, De Bonis Michele, Zangrillo Alberto, Fiore Gianfranco B, Redaelli Alberto, Slepian Marvin J, Pappalardo Federico

СтатьяНаблюдательное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: To correlate the dynamics of platelet activation with the development of thromboembolic events in patients with continuous-flow left ventricular assist device (cf-LVAD).

METHODS AND

RESULTS

The platelet activity state (PAS) assay was utilized to evaluate platelet activation in 68 cf-LVAD patients implanted with the HeartMate II (n = 15, 22%), HeartMate 3 (n = 15, 22%), or HeartWare HVAD (n = 38, 56%). PAS was measured preoperatively, early post-implant, and at long-term follow-up (1, 3, 6, 12, 18, and 24 months post-implant). PAS was also measured at the occurrence of adverse events in patients who developed thrombotic complications. Data on patient demographics, medical history, antithrombotic therapy, and coagulation parameters were also analysed. Over a median follow-up of 602 (234-942) days, PAS values did not increase over time in the overall population (P = 0.15). However, PAS measured at event was 15-fold higher in the six patients (9%) who suffered pump thrombosis (n = 2) or ischaemic stroke (n = 4) vs. the rest of the population [6.67% (5.59%-11.98%) vs. 0.45% (0.33%-0.75%); P = 0.012], despite comparable coagulation profile. Pre-implant PAS values were 4.5-fold higher in these patients [1.90% (1.24%-3.17%) vs. 0.42% (0.32%-0.72%); P = 0.006]. Neither preoperative variables nor the type of the pump or the antiplatelet strategy were associated with a higher risk of complications.

CONCLUSIONS

Thrombotic events are associated with altered PAS values. Moreover, baseline elevated PAS values in patients who developed thrombotic events suggest patient-specific tendency to post-implant thromboembolic complications. Prospectively, systematic monitoring of PAS might guide the development of refined patient-tailored antithrombotic strategies and the technological improvement of LVAD design.

Для цитирования: Consolo Filippo, Sferrazza Giulia, Motolone Giulia, Contri Rachele, Valerio Lorenzo, Lembo Rosalba, Pozzi Loris, Della Valle Patrizia, De Bonis Michele, Zangrillo Alberto, Fiore Gianfranco B, Redaelli Alberto, Slepian Marvin J, Pappalardo Federico. Platelet activation is a preoperative risk factor for the development of thromboembolic complications in patients with continuous-flow left ventricular assist device.. European journal of heart failure. 2017. DOI: 10.1002/ejhf.1113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.