Аннотация

BACKGROUND / PURPOSE: The Lotus valve (Boston Scientific, Natick, MA, USA) is a contemporary transcatheter aortic valve implantation (TAVI) device that is fully repositionable and retrievable to aid implantation and optimise procedural results. The ability to implant the device without routine pre-dilatation is another possible advantage reducing associated risks and procedure times. The aim of this study is to report procedural and 30-day outcomes following TAVI in a consecutive patient group presenting with severe symptomatic aortic stenosis with the Lotus valve system without routine pre-dilatation.

METHODS / MATERIALS: 146 consecutive patients that underwent TAVI at the John Radcliffe Hospital, Oxford between January 2015 - December 2016 were retrospectively analysed.

RESULTS

The mean age was 81.1±7.4 years and the mean logistic EuroSCORE was 14.6±10. 134 (91.8%) of patients were treated under conscious sedation. 144 (98.6%) of procedures were successful. Two patients (1.4%) died during the follow-up period. None or mild residual aortic regurgitation was achieved in 98.6% of patients. The mean and peak transvalvular gradients were 8.6±3.6mmHg and 16.6±6.6mmHg respectively. Eight patients (5.5%) suffered a stroke. Over time, there was a reduction in major vascular complications (14.3% vs. 2.2%, p=0.03) and a trend toward shorter procedure times (97.6±44.3 vs. 86.8±31.4 minutes, p=0.14) and the administration of less contrast (104.4±45.2 vs. 91.7±37.6 millilitres, p=0.16). The overall new pacemaker implantation rate was 36.3%.

CONCLUSIONS

The use of the Lotus valve as a 'workhorse' device without routine pre-dilatation is safe and efficacious and is associated with a very low incidence of residual aortic regurgitation and acceptable transvalvular haemodynamics.

Для цитирования: Ruparelia Neil, Thomas Katharine, Newton James D, Grebenik Kate, Keiralla Amar, Krasopoulos George, Sayeed Rana, Banning Adrian P, Kharbanda Rajesh K. Procedural and thirty-day outcomes following transfemoral implantation of the fully repositionable and retrievable Lotus valve without routine pre-dilatation in a consecutive patient cohort: a single-center experience.. Cardiovascular revascularization medicine : including molecular interventions. 2017. DOI: 10.1016/j.carrev.2017.10.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.