MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-017-15396-4

Медицинская библиотека · Scientific reports · 2017

Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis.

Liao Yan-Biao, Li Yi-Jian, Jun-Li Li, Zhao Zhen-Gang, Wei Xin, Tsauo Jiay-Yu, Xiong Tian-Yuan, Xu Yuan-Ning, Feng Yuan, Chen Mao

СтатьяМетаанализПоддержка исследования: вне правительства СШАСистематический обзорПеревод пока не подготовлен

Аннотация

The aim of this study was to investigate the incidence, predictors and outcome of prosthesis-patient mismatch (PPM) following transcatheter aortic valve replacement (TAVR). A total of 30 articles incorporating 4,691 patients were identified. The pooled incidences of overall, moderate and severe PPM following TAVR were 33.0%, 25.0% and 11.0% respectively. Medtronic CoreValve (MCV) had lower incidence of overall (32% vs: 40%, P < 0.0001) and moderate (23% vs 32%, P < 0.0001) than Edwards Sapien (ESV). PPM was associated with a younger age, smaller annulus diameter and lower left ventricular ejection fraction in comparison with those patients without PPM. Post-dilation (OR, 0.51, 95% CI, 0.38 to 0.68, p < 0.001) during TAVR would decrease the incidence of PPM. Although PPM was common after TAVR, no significant differences were observed both in short- and mid-term all-cause mortality (30 day: OR: 1.1, 95% CI, 0.70 to 1.73 and 2 year: OR: 1.01, 95% CI, 0.74 to 1.38) between patients with PPM and those without PPM. In conclusion, despite being common after TAVR, the incidence of PPM was lower than that of surgical aortic valve replacement (SAVR) and decreased with the experience accumulating, and PPM was not seen to impact on short- and mid-term survival, regardless of its magnitude.

Для цитирования: Liao Yan-Biao, Li Yi-Jian, Jun-Li Li, Zhao Zhen-Gang, Wei Xin, Tsauo Jiay-Yu, Xiong Tian-Yuan, Xu Yuan-Ning, Feng Yuan, Chen Mao. Incidence, Predictors and Outcome of Prosthesis-Patient Mismatch after Transcatheter Aortic Valve Replacement: a Systematic Review and Meta-analysis.. Scientific reports. 2017. DOI: 10.1038/s41598-017-15396-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.