MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2017.07.714

Медицинская библиотека · Journal of the American College of Cardiology · 2017

Transcatheter Mitral Valve Replacement for Degenerated Bioprosthetic Valves and Failed Annuloplasty Rings.

Yoon Sung-Han, Whisenant Brian K, Bleiziffer Sabine, Delgado Victoria, Schofer Niklas, Eschenbach Lena, Fujita Buntaro, Sharma Rahul, Ancona Marco, Yzeiraj Ermela, Cannata Stefano, Barker Colin, Davies James E, Frangieh Antonio H, Deuschl Florian, Podlesnikar Tomaz, Asami Masahiko, Dhoble Abhijeet, Chyou Anthony, Masson Jean-Bernard, Wijeysundera Harindra C, Blackman Daniel J, Rampat Rajiv, Taramasso Maurizio, Gutierrez-Ibanes Enrique, Chakravarty Tarun, Attizzani Guiherme F, Kaneko Tsuyoshi, Wong S Chiu, Sievert Horst, Nietlispach Fabian, Hildick-Smith David, Nombela-Franco Luis, Conradi Lenard, Hengstenberg Christian, Reardon Michael J, Kasel Albert Markus, Redwood Simon, Colombo Antonio, Kar Saibal, Maisano Francesco, Windecker Stephan, Pilgrim Thomas, Ensminger Stephan M, Prendergast Bernard D, Schofer Joachim, Schaefer Ulrich, Bax Jeroen J, Latib Azeem, Makkar Raj R

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Limited data exist regarding transcatheter mitral valve replacement (TMVR) for patients with failed mitral valve replacement and repair.

OBJECTIVES

This study sought to evaluate the outcomes of TMVR in patients with failed mitral bioprosthetic valves (valve-in-valve [ViV]) and annuloplasty rings (valve-in-ring [ViR]).

METHODS

From the TMVR multicenter registry, procedural and clinical outcomes of mitral ViV and ViR were compared according to Mitral Valve Academic Research Consortium criteria.

RESULTS

A total of 248 patients with mean Society of Thoracic Surgeons score of 8.9 ± 6.8% underwent TMVR. Transseptal access and the balloon-expandable valve were used in 33.1% and 89.9%, respectively. Compared with 176 patients undergoing ViV, 72 patients undergoing ViR had lower left ventricular ejection fraction (45.6 ± 17.4% vs. 55.3 ± 11.1%; p < 0.001). Overall technical and device success rates were acceptable, at 92.3% and 85.5%, respectively. However, compared with the ViV group, the ViR group had lower technical success (83.3% vs. 96.0%; p = 0.001) due to more frequent second valve implantation (11.1% vs. 2.8%; p = 0.008), and lower device success (76.4% vs. 89.2%; p = 0.009) due to more frequent reintervention (16.7% vs. 7.4%; p = 0.03). Mean mitral valve gradients were similar between groups (6.4 ± 2.3 mm Hg vs. 5.8 ± 2.7 mm Hg; p = 0.17), whereas the ViR group had more frequent post-procedural mitral regurgitation moderate or higher (19.4% vs. 6.8%; p = 0.003). Furthermore, the ViR group had more frequent life-threatening bleeding (8.3% vs. 2.3%; p = 0.03), acute kidney injury (11.1% vs. 4.0%; p = 0.03), and subsequent lower procedural success (58.3% vs. 79.5%; p = 0.001). The 1-year all-cause mortality rate was significantly higher in the ViR group compared with the ViV group (28.7% vs. 12.6%; log-rank test, p = 0.01). On multivariable analysis, failed annuloplasty ring was independently associated with all-cause mortality (hazard ratio: 2.70; 95% confidence interval: 1.34 to 5.43; p = 0.005).

CONCLUSIONS

The TMVR procedure provided acceptable outcomes in high-risk patients with degenerated bioprostheses or failed annuloplasty rings, but mitral ViR was associated with higher rates of procedural complications and mid-term mortality compared with mitral ViV.

Для цитирования: Yoon Sung-Han, Whisenant Brian K, Bleiziffer Sabine, Delgado Victoria, Schofer Niklas, Eschenbach Lena, Fujita Buntaro, Sharma Rahul, Ancona Marco, Yzeiraj Ermela, Cannata Stefano, Barker Colin, Davies James E, Frangieh Antonio H, Deuschl Florian, Podlesnikar Tomaz, Asami Masahiko, Dhoble Abhijeet, Chyou Anthony, Masson Jean-Bernard, Wijeysundera Harindra C, Blackman Daniel J, Rampat Rajiv, Taramasso Maurizio, Gutierrez-Ibanes Enrique, Chakravarty Tarun, Attizzani Guiherme F, Kaneko Tsuyoshi, Wong S Chiu, Sievert Horst, Nietlispach Fabian, Hildick-Smith David, Nombela-Franco Luis, Conradi Lenard, Hengstenberg Christian, Reardon Michael J, Kasel Albert Markus, Redwood Simon, Colombo Antonio, Kar Saibal, Maisano Francesco, Windecker Stephan, Pilgrim Thomas, Ensminger Stephan M, Prendergast Bernard D, Schofer Joachim, Schaefer Ulrich, Bax Jeroen J, Latib Azeem, Makkar Raj R. Transcatheter Mitral Valve Replacement for Degenerated Bioprosthetic Valves and Failed Annuloplasty Rings.. Journal of the American College of Cardiology. 2017. DOI: 10.1016/j.jacc.2017.07.714.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.