Long-term follow-up of continuous flow left ventricular assist devices: complications and predisposing risk factors.
Аннотация
PURPOSE: To assess LVAD complications and their overall effect on mortality and determine factors associated with development of early and long-term complications.
METHODS
A retrospective cohort study of patients who underwent continuous flow LVAD placement between January 1, 2000 and November 30, 2013 was performed. The incidence of complications (sepsis or bacteremia, driveline infections, gastrointestinal bleeding, pump thrombosis, cerebrovascular accidents and anemia requiring transfusion) was collected and logistic regression and Cox proportional hazards analyses were performed.
RESULTS
108 patients met our inclusion criteria. Median length of follow-up was 2.2 years. In univariable logistic regression analysis, higher blood urea nitrogen (BUN), creatinine clearance <60, no prior inotrope use, higher INTERMACS class and lower platelet count were associated with early complications. On multivariable analysis, factors associated with early complications included higher BUN (odds ratio (OR) 1.03, 95% confidence interval (CI) 1.001-1.06 per mg/dL BUN), no prior inotrope use (OR 4.92, 95% CI 1.64- 14.7) and lower platelet count (OR 4.29, 95% CI 1.45-12.7 <200 10(3) cu mm); 24% of patients developed early complications and 18.5% developed an early and late complication. Early complications were significantly associated with death (p = 0.017). The presence of 2 or more complications was associated with a 2.7-fold increase in the odds of death (p = 0.016) and odds of death increased by 20% with each subsequent complication (p = 0.004).
CONCLUSIONS
LVADs are associated with significant long-term complications including stroke and sepsis and minimizing time on LVADs may decrease the risk of complications and subsequent morbidity and mortality.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.