MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cjca.2019.04.015

Медицинская библиотека · The Canadian journal of cardiology · 2019

Left Atrial Function Using Cardiovascular Magnetic Resonance Imaging Independently Predicts Life-Threatening Arrhythmias in Patients Referred to Receive a Primary Prevention Implantable Cardioverter Defibrillator.

Lydell Carmen P, Mikami Yoko, Homer Kai, Peng Mingkai, Cornhill Aidan, Rajagopalan Archa, Arasaratnam Punitha, Cowan Karen, Roberts Andrew, Sumner Claire, Heydari Bobak, Howarth Andrew G, Exner Derek, White James A

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

In this study we aimed to investigate left atrial (LA) function, measured from routine cine cardiovascular magnetic resonance imaging, to determine its value for the prediction of sudden cardiac death (SCD) or appropriate implantable cardioverter defibrillator (ICD) shock in patients who received primary prevention ICD implantation.

METHODS

We studied 203 patients with ischemic or idiopathic nonischemic dilated cardiomyopathy who underwent cardiovascular magnetic resonance imaging before primary prevention ICD implantation. LA volumes were measured at end-diastole and end-systole from 4- and 2-chamber cine images, and LA emptying function (LAEF) calculated. Patients were followed for the primary composite end point of SCD or appropriate ICD shock.

RESULTS

Mean age was 61 ± 12 years with a mean left ventricular ejection fraction of 24 ± 7%. The mean LAEF was 27 ± 15% (range, 0.9%-73%). At a median follow-up of 1639 days, 35 patients (17%) experienced the primary composite outcome. LAEF was strongly associated with the primary outcome (P = 0.001); patients with an LAEF ≤ 30% experienced a cumulative event rate of 26.1% vs 5.7% (hazard ratio, 5.5; P < 0.001) in patients above this cutoff. This finding was maintained in multivariable analysis (hazard ratio, 4.7; P = 0.002) and was consistently shown in the ischemic and nonischemic dilated cardiomyopathy subgroups.

CONCLUSIONS

LAEF is a simple, powerful, and independent predictor of SCD in patients being referred for primary prevention ICD implantation.

Для цитирования: Lydell Carmen P, Mikami Yoko, Homer Kai, Peng Mingkai, Cornhill Aidan, Rajagopalan Archa, Arasaratnam Punitha, Cowan Karen, Roberts Andrew, Sumner Claire, Heydari Bobak, Howarth Andrew G, Exner Derek, White James A. Left Atrial Function Using Cardiovascular Magnetic Resonance Imaging Independently Predicts Life-Threatening Arrhythmias in Patients Referred to Receive a Primary Prevention Implantable Cardioverter Defibrillator.. The Canadian journal of cardiology. 2019. DOI: 10.1016/j.cjca.2019.04.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.