CONTEXT: Continuous ambulatory peritoneal dialysis (CAPD) has been widely used as an effective therapy in the management of patients with end-stage renal disease. Long-term use of CAPD needs methods with low incidence of catheter-related complications. Moreover, some complications may cause failure of fluid drainage and treatment interruption.

AIMS: We have innovated and studied a new minimal-invasive method of malfunctioning peritoneal catheter repair.

MATERIALS AND

METHODS

Thirty-five patients agreed to undergo catheter rescue operation by this new method during 2004 and 2012. Under local anesthesia and light sedation, access to the abdominal cavity was made, the catheter and wrapped omentum grasped and the tip of catheter was released, debris were removed and the catheter was directed toward the pelvic floor with a finger guide. The patients were followed after catheter salvage up to the end of study (April 2012). PD catheter function restored to the normal level in 28 (80%) of patients, and PD was started 1-2 days after the procedure.

RESULTS

All patients had an uneventful recovery. PD catheter function was restored to the normal level in 28 (80%) patients, and PD was started 1-2 days after the procedure. Of these patients, 10 (35%) died of reasons unrelated to catheter or catheter complications; 7 (25%) were ultimately referred for kidney transplant; 8 (29%) continued PD up to the end of this study with no problem, and only 3 (11%) due to catheter complications. Catheter function did not restore to the normal level in seven patients (20%); however, six patients continued PD for 1-18 months with the catheter.

CONCLUSIONS

Comparing the advantages and disadvantages of this method to the previous laparoscopically repaired catheter, we concluded that this new method is efficient, and is a suitable way for malfunctioning PD catheter salvage.

Для цитирования: Beig Ali Akbar, Marashi Sayed Mahdi, Asadabadi Hojatollah Raji, Sharifi Ali, Zarch Zohre Nasiri. A novel method for salvage of malfunctioning peritoneal dialysis catheter.. Urology annals. 2014. DOI: 10.4103/0974-7796.130646.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.