MedElevator Войти в исследования
← Поиск публикаций

DOI 10.12779/dnd.2025.24.2.91

Медицинская библиотека · Dementia and neurocognitive disorders · 2025

Reproducibility of Plasma Biomarker Measurements Across Laboratories: Insights Into ptau217, GFAP, and NfL.

Kang Heekyoung, Woo Sook-Young, Shin Daeun, Yim Sohyun, Lee Eun Hye, Ryu Hyunchul, Chu Bora, Zetterberg Henrik, Blennow Kaj, Yun Jihwan, Na Duk L, Kim Hee Jin, Jang Hyemin, Kim Jun Pyo, K-ROAD Study Groups

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Plasma biomarkers, including phosphorylated tau (ptau217), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL), are promising tools for detecting Alzheimer's disease (AD) pathology. However, cross-laboratory reproducibility remains a challenge, even when using identical analytical platforms such as single-molecule array (Simoa). This study aimed to compare plasma biomarker measurements (ptau217, GFAP, and NfL) between 2 laboratories, the University of Gothenburg (UGOT) and DNAlink, and evaluate their associations with amyloid positron emission tomography (PET) imaging.

METHODS

Plasma biomarkers were measured using Simoa platforms at both laboratories: the UGOT and DNAlink Incorporation. Diagnostic performance for predicting amyloid PET positivity, cross-laboratory agreement, and the impact of normalization techniques were assessed. Bland-Altman plots and correlation analyses were employed to evaluate agreement and variability.

RESULTS

Plasma ptau217 concentrations exhibited strong correlations with amyloid PET global centiloid values, with comparable diagnostic performance between laboratories (area under the curve=0.94 for UGOT and 0.95 for DNAlink). Cross-laboratory agreement for ptau217 was excellent (r=0.96), improving further after natural log transformation. GFAP and NfL also demonstrated moderate to strong correlations (r=0.86 for GFAP and r=0.99 for NfL), with normalization reducing variability.

CONCLUSIONS

Plasma biomarker measurements were consistent across laboratories using identical Simoa platforms, with strong diagnostic performance and improved agreement after normalization. These findings support the scalability of plasma biomarkers for multi-center studies and underscore their potential for standardized applications in AD research and clinical practice.

Для цитирования: Kang Heekyoung, Woo Sook-Young, Shin Daeun, Yim Sohyun, Lee Eun Hye, Ryu Hyunchul, Chu Bora, Zetterberg Henrik, Blennow Kaj, Yun Jihwan, Na Duk L, Kim Hee Jin, Jang Hyemin, Kim Jun Pyo, K-ROAD Study Groups. Reproducibility of Plasma Biomarker Measurements Across Laboratories: Insights Into ptau217, GFAP, and NfL.. Dementia and neurocognitive disorders. 2025. DOI: 10.12779/dnd.2025.24.2.91.