m+Medelevator.RU
← Поиск публикаций
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology · 2016

Inner Ear Active Hearing Device in Non-Otosclerotic, Severe, Mixed Hearing Loss.

Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Barbara Maurizio, Volpini Luigi, Covelli Edoardo, Filippi Chiara, Monini Simonetta

Аннотация

OBJECTIVE: To verify the efficacy of a powerful active hearing device in a patient different from far-advanced otosclerosis, specifically when the stapes footplate is mobile.

PATIENT: A patient with severe-to-profound mixed hearing loss, who was not benefiting from the use of a conventional hearing aid, was selected for an inner ear active implant. This was justified by a bone conductive threshold above 60 dB, which had discouraged any other rehabilitative solutions such as a bone conductive implant, or an active middle ear implant (AMEI).

INTERVENTION: The hearing device was surgically applied using a combined transmastoid/transcanal approach. During surgery, a mobile stapes were found and was perforated for the insertion of a piston prosthesis, crimped on the new-incus of the device.

MAIN OUTCOME MEASURE: The bone conduction threshold was assessed postoperatively to identify any possible surgery-related hearing deterioration. Pure tone audiometry was conducted in a sound field, and a speech reception threshold test was performed with the contralateral ear masked. The hearing outcome was assessed soon after the implant activation (6 weeks after surgery), and 6 months after surgery.

RESULTS: Upon activation of the device, a PTA of 45 dB was obtained (at 0.5, 1, 2 and 4 kHz). At 6 months after surgery, the speech discrimination score reached 90% at 80 dB SPL.

CONCLUSION: The application of the Codacs device has shown to be compatible with a mobile stapes footplate, as demonstrated in this report. The footplate perforation did not cause any further hearing deterioration, and has allowed to achieve a favorable auditory outcome.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты