MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jnnp.2010.205856

Медицинская библиотека · Journal of neurology, neurosurgery, and psychiatry · 2010

IVIG blocks complement deposition mediated by anti-GM1 antibodies in multifocal motor neuropathy.

Yuki N, Watanabe H, Nakajima T, Späth P J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The pathogenesis of multifocal motor neuropathy (MMN) has yet to be established. MMN patients often carry anti-GM1 IgM antibodies, suggesting an autoimmune process involving complement. Intravenous immunoglobulin (IVIG) is the first line treatment, but its action mechanism is unknown.

OBJECTIVE

To test whether anti-GM1 IgM antibodies in MMN sera activate complement, inducing and propagating the disease and whether IVIG inhibits complement activation, resulting in clinical improvement.

METHODS

Sera with anti-GM1 IgM but not IgG or IgA reactivity were obtained from 13 patients with MMN. We tested whether their anti-GM1 IgM antibodies produced complement component deposits on GM1-coated microtiter plates and whether IVIG blocks such deposition.

RESULTS

C1q, C4b, C3b and C5b-9 were deposited on GM1-coated wells. Their depositions were highly correlated with anti-GM1 IgM antibody titre. IVIG reduced the deposition of these complement components dose-dependently.

CONCLUSIONS

Anti-GM1 IgM antibodies bound to GM1 and activated complement in vitro. The results together with earlier data from our group suggest that IgM-induced, complement-mediated injury occurs at the nodes of Ranvier in peripheral motor nerves and generates conduction block and muscle weakness. In vitro IVIG inhibited this type of complement activation, suggesting that in vivo, the resulting reduction in membrane attack complex-mediated damage leads to improved muscle strength.

Для цитирования: Yuki N, Watanabe H, Nakajima T, Späth P J. IVIG blocks complement deposition mediated by anti-GM1 antibodies in multifocal motor neuropathy.. Journal of neurology, neurosurgery, and psychiatry. 2010. DOI: 10.1136/jnnp.2010.205856.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.