MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eum002

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2007

Brugada-like electrocardiographic pattern and ventricular fibrillation in a patient with primary hyperparathyroidism.

Wu Lung-Sheng, Wu Chia-Tung, Hsu Lung-An, Luqman Nazar, Kuo Chi-Tai

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

There are several causes for ST segment abnormalities in leads V1 to V3. Hypercalcaemia and Brugada syndrome are among them. Both are known to produce ventricular arrhythmia, albeit only rare cases have been reported with documented evidence of ventricular arrhythmias in association with a hypercalcaemic crisis but none when hypercalcaemic coexists with Brugada syndrome. We describe a patient with primary hyperparathyroidism who presented with ventricular fibrillation, and the ECG showed changes similar to Brugada syndrome. The provocation test with flecainide was conducted twice. This was positive, both before and after parathyroidectomy when serum calcium and parathormone levels had normalized. The patient was treated for hypercalcaemia and underwent parathyroidectomy. This is the first report of oral flecainide test unmasking the diagnostic coved Brugada ECG pattern in a patient with primary hyperparathyroidism and raising attention to hypercalcaemia as a potential trigger for life-threatening arrhythmia in Brugada syndrome.

Для цитирования: Wu Lung-Sheng, Wu Chia-Tung, Hsu Lung-An, Luqman Nazar, Kuo Chi-Tai. Brugada-like electrocardiographic pattern and ventricular fibrillation in a patient with primary hyperparathyroidism.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2007. DOI: 10.1093/europace/eum002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.