MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/19714009211041524

Медицинская библиотека · The neuroradiology journal · 2021

Diagnostic utility of parasagittal measurements of tonsillar herniation in Chiari I malformation.

Ebrahimzadeh Seyed Amir, Loth Francis, Ibrahimy Alaaddin, Nwotchouang Blaise Simplice Talla, Bhadelia Rafeeque A

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: Although the cerebellar tonsils are parasagittal structures, the extent of tonsillar herniation (ETH) in Chiari I malformation (CMI) is currently measured in the midsagittal plane. We measured the ETH of each cerebellar tonsil in the parasagittal plane and assessed their diagnostic utility by comparing them to the midsagittal ETH measurements in predicting cough-associated headache (CAH), an indicator of clinically significant disease in CMI.

METHODS

Eighty-five CMI patients with 3D-MPRAGE images were included. Neurosurgeons determined the presence of CAH. Sagittal images were used to measure ETH in the midsagittal (MS_ETH) and parasagittal planes (by locating tonsillar tips on each side on reformatted coronal images). Given the parasagittal ETH (PS_ETH) asymmetry in the majority of cases, they were considered Smaller_PS_ETH or Larger_PS_ETH. The accuracy of ETH measurements was assessed by the receiver operating characteristic (ROC) curve.

RESULTS

Of 85 patients, 46 reported CAH. ROC analysis showed an area under the curve (AUC) of 0.78 for Smaller_PS_ETH significantly better than 0.65 for MS-ETH in predicting CAH (p = 0.001). An AUC of 0.68 for Larger_PS_ETH was not significantly different from MS_ETH. The sensitivity and specificity of predicting CAH were 87% and 28% for MS_ETH >6 mm versus 90% and 46% for Smaller_PS_ETH >6 mm, and 52% and 67% for MS_ETH >9 mm versus 48% and 87% for Smaller_PS_ETH >9 mm. At ETH >15 mm, no differences were seen between the measurements.

CONCLUSIONS

Diagnostic utility of ETH measurements in detecting clinically significant CMI can be improved by parasagittal measurements of the cerebellar tonsillar herniation.

Для цитирования: Ebrahimzadeh Seyed Amir, Loth Francis, Ibrahimy Alaaddin, Nwotchouang Blaise Simplice Talla, Bhadelia Rafeeque A. Diagnostic utility of parasagittal measurements of tonsillar herniation in Chiari I malformation.. The neuroradiology journal. 2021. DOI: 10.1177/19714009211041524.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.