DOI 10.1177/021849230401200109

Медицинская библиотека · Asian cardiovascular & thoracic annals · 2004

Predicting the response to lung volume reduction surgery using scintigraphy.

Shigemura Norihisa, Akashi Akinori, Nakagiri Tomoyuki, Ohta Mitsunori, Matsuda Hikaru

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

This study was conducted to evaluate the use of quantitative scintigraphy with a newly designed marker to assess and predict the efficacy of lung volume reduction surgery in treating emphysema. In a series of 50 patients with severe emphysema who underwent the operation, ventilation/perfusion scintigraphy was performed and 2 markers of area ratio and lung uniformity were measured before and 6 months after surgery. The markers were correlated with the results of pulmonary function tests. The histopathological subtype of emphysema was also determined in the resected specimen and related to improvement in the markers. The markers were closely related to improvement in forced expiratory volume in 1 second, with the highest correlation being the marker lung uniformity measured by perfusion scintigraphy. Improvement in this marker was significantly greater in centrilobular than in panlobular emphysema. This quantitative method of scintigraphy could provide an excellent reflection of surgical efficacy as well as predict the surgical outcome. Additionally, it provides a mechanistic explanation for the differential improvement between the histopathological subtypes of emphysema following surgery.

Для цитирования: Shigemura Norihisa, Akashi Akinori, Nakagiri Tomoyuki, Ohta Mitsunori, Matsuda Hikaru. Predicting the response to lung volume reduction surgery using scintigraphy.. Asian cardiovascular & thoracic annals. 2004. DOI: 10.1177/021849230401200109.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.