Meals and Room Temperature Storage do not Significantly Affect Feasibility of Direct RT-PCR Tests for SARS-CoV-2 Using Saliva.

Tsuchiya Koji, Hosaka Yoshie, Takahashi Toshihiro, Chonan Masayoshi, Makita Yuko, Katayama Isana, Ai Tomohiko, Idei Mayumi, Horiuchi Yuki, Yamatani Kotoko, Wakita Mitsuru, Misawa Shigeki, Okuzawa Atsushi, Miida Takashi, Naito Toshio, Takahashi Kazuhisa, Tabe Yoko

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) using saliva samples has emerged as a preferred technique since sample collection is easy and noninvasive. In addition, several commercial high-throughput PCR kits that do not require RNA extraction/purification have been developed and are now available for testing saliva samples. However, an optimal protocol for SARS-CoV-2 RT-PCR testing of saliva samples using the RNA extraction/purification-free kits has not yet been established. The aim of this study was to establish optimal preanalytical conditions, including saliva sample collection, storage, and dilution for RNA extraction/purification-free RT-PCR (direct RT-PCR).

METHODS

Patients suspected with COVID-19 from March 02 to August 31, 2020, were enrolled in this study. A total of 248 samples, including 43 nasopharyngeal swabs and 205 saliva samples, were collected from 66 patients (37 outpatients and 29 inpatients) and tested using the 2019 Novel Coronavirus Detection Kit (nCoV-DK, Shimadzu Corporation, Kyoto, Japan).

RESULTS

The detection results obtained using nasopharyngeal swabs and saliva samples matched 100%. The sampling time, i.e., either awakening time or post-breakfast, had no significant effect on the viral load of the saliva samples. Although saliva samples are routinely diluted to reduce viscosity, we observed that dilution negatively affected PCR sensitivity. Saliva samples could be stored at room temperature (25°C) for 24 hours or at 4°C for up to 48 hours.

CONCLUSIONS

This study demonstrated the appropriate conditions of saliva sample collection, processing, and storage, and indicated that the nCoV-DK is applicable to saliva samples, making the diagnosis method simple and safe.

Для цитирования: Tsuchiya Koji, Hosaka Yoshie, Takahashi Toshihiro, Chonan Masayoshi, Makita Yuko, Katayama Isana, Ai Tomohiko, Idei Mayumi, Horiuchi Yuki, Yamatani Kotoko, Wakita Mitsuru, Misawa Shigeki, Okuzawa Atsushi, Miida Takashi, Naito Toshio, Takahashi Kazuhisa, Tabe Yoko. Meals and Room Temperature Storage do not Significantly Affect Feasibility of Direct RT-PCR Tests for SARS-CoV-2 Using Saliva.. Clinical laboratory. 2022. DOI: 10.7754/clin.lab.2021.210451.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.